P:\INSTALLATION INST\DORMA\INST-AC217 (version 2).vsd REV A 08-09 Page 1
AC217 STAND-ALONE KEYPAD
INSTALLATION INSTRUCTIONS
Try the new code: Press 1493#
Basic Programming:
1. Enter Programming Mode
Power unit up with (LPJ) jumper in the ON position, remove, replace
jumper to OFF position (puts you in the program mode).
Enter “09876#”
New Master Code is 9876.
2. Program User Code
Enter 9876* followed by 1 user ID number (01-99) pin number #
Example: 9876 * 1 01 7412# (this is user 01 with pin number 7412).
User Number from 1 – 99. PIN code 4-8 digits.
3. Set Main Relay Time
Press 40 05 # *. Time (1-999 sec.)
Additional Programming Optional:
Delete User
Enter Master Code * 1 User Number # *. Deletes user.
Change Master Code
Enter Master Code * 0 New Master # *. Master code is changed.
Reset to factory default settings
Enter Master Code * Press 8901# *. Erases all programming except
Master Code.
AC217 EXAMPLE PROGRAMMING
Basic Programming:
The following steps will set the AC217 to:
User 02 PIN code 1493
Unlock for 5 seconds
Programming:
1. Enter 9876* 1 02 1493#
2. Enter 40 05# *
Action
Enters Programming Mode and assigns User 02 the PIN
Code of 1493, Master Code is 9876.
LPJ JUMPER
DORMA ARCHITECTURAL HARDWARE
DORMA Drive, Drawer AC Reamstown, PA. 17567
(800) 523-8483 * Fax: (800) 274-9724
www.dorma-usa.com
Question and Answer IconNeed help?

Do you have a question about the Dorma AC217 and is the answer not in the manual?

Dorma AC217 Specifications

General IconGeneral
BrandDorma
ModelAC217
CategoryKeypad
LanguageEnglish

Summary

AC217 Stand-Alone Keypad Installation Instructions

Basic Programming

Guides through initial setup including entering programming mode, programming user codes, and setting main relay time.

Additional Programming Options

Covers optional functions such as deleting users, changing master codes, and resetting to factory defaults.

AC217 Example Programming

Programming Steps

Demonstrates setting a specific user code (02 PIN 1493) and unlock time (5 seconds).

Action Result

Confirms the outcome of the example programming: User 02, Master Code 9876.

AC217 Keypad Specifications

Power and Outputs

Details operational voltage, current drain, and relay/tamper output specifications.

Inputs and Code Operation

Outlines power input requirements, egress input, and user code capacity/entry limits.

Factory Defaults

Lists default settings for master code, user code length, relay time, and lockout parameters.

Status Indicators

Explains buzzer and LED feedback for various operational states and programming modes.

Master Code Bypass (LPJ Jumper)

Bypass Procedure

Step-by-step instructions to use the LPJ jumper for bypassing a forgotten master code.