Dormakaba System 6000 - Troubleshooting Encoder Issues; Resolving Connection Problems; Resolving Configuration Problems

Dormakaba System 6000
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 dormakaba RFID Encoder PK3695 03-19
Troubleshooting
USB cable must be attached whenever you are configuring the encoder.
After Configuration: Connect a USB Cable for USB communication or an Ethernet cable with POE for
TCP/IP communication.
**Do not connect USB cable to PC when configured for TCP/IP communication**
**If ethernet connection is not POE, use the included USB power adapter for power**
Connection Issues:
Ensure the encoder’s Station ID is selected in the Client Terminal Settings
Ensure that Kaba Encoder USB Bridge Service is running
Ensure that Kaba IP Encoder Service is running (KIPES)
Ensure the CRS is running
Ensure you are using the correct cable (USB or Ethernet)
Confirm that the minimum prerequisite software (System 6000 5.6.8.0) and firmware (Encoder
V.1.012) is installed
Remove the power from the encoder, wait five seconds and power it back up (Repeat as
necessary)
Restart KIPES and Kaba Encoder USB Bridge Service
Restart PC
Configuration Issues:
Make sure that the encoder is not already assigned in the CRS
Make sure that the USB cable (P/N 71680) is attached. (Third party cables may not function
properly)
Ensure station ID entered was less than 16 characters
If server not correctly assigned on workstation, do the following:
Edit the Saflok.ini file located in the SaflokV4 folder to enter the server IP address under the
database section. Save the file and test encoder function.
Example:
[Database]
LinkPath=\\xx.xxx.xxx.xx\SaflokData\
MsgLinkPath=\\xx.xxx.xxx.xx\SaflokData\