Motionless
Non alarm state: the device is in motion.
Automatic sequence: Yes.
Emergency call sequence
1. The phone is motionless (which could indicate unconsciousness of
the carrier) for more than 15 seconds.
2. The emergency sequence is started after 30 seconds.
3. To cancel, put the phone in motion within 5 seconds OR press Yes to
cancel. If no action:
1. An assistance text message (SMS) is sent to all recipients.
2. A positioning text message (SMS) is sent to all recipients.
3. The first recipient in the list is dialled. If the call is not answered
within 25 seconds, the next number is dialled. Dialling is re-
peated 3 times or until the call is answered, or until
is
pressed.
Horizontal & motionless
Combination of horizontal and motionless.
Vertical & motionless
Combination of vertical and motionless.
Activate Mandown
1. Press Menu and select
IUP:
Off to disable.
Horizontal
Vertical
Motionless
Hor. or motionless (combination of horizontal and motionless).
Ver. or motionless (combination of vertical and motionless).
2. Press OK to confirm.