Page 4
800-523-8499
www.dosatronusa.com
Proper protection, such as gloves, eye wear, and aprons, are recommended when disassembling a Dosatron.
Step 12: Install the new seal (Part #: J009) into the groove.
Step 11: To replace the seal, pinch and roll it off of the plunger.
Step 10: Take a close look at the plunger seal for nicks, scratches,
or wear. If you see damage or don’t remember the last time you
changed the seal, just replace it now.