PLUMBING
The drain outlet is specially molded out of PVC material
and is located in the front-center of the case for conve-
nient access. The “P” trap, furnished with the case, is con-
structed of schedule 40 PVC pipe (Fig. 13). Care should
be given to ensure that all connections are water-tight and
sealed with the appropriate PVC or ABS cement.
ELECTRICAL
Electrical hookups are made to a junction box located ei-
ther at the bottom-front-left of the case (Fig. 14), at the top-
rear-left of the case (Fig. 15) or to the raceway running
along the bottom-front of the case.
For case-to-case wiring, run conduit between the junction
boxes or run wiring through the raceway. When connecting
to the junction box on the bottom-left side of the case, eld
wiring should exit box from the right side (furthest away
from case wiring) to allow more room inside for wiring con-
nections. For more detailed electrical wiring information,
see Appendix E.
The drain lines can be run left or right of the tee with the
proper pitch to satisfy local drainage requirements. Since
the kickplate is shipped loose with the case, you should
have open access to the drain line area during installation.
If the kickplate has been installed, you will nd it very easy
to remove. Simply lift the kickplate up from the "J" rail and
pull it out, away from the case (see Trim Out section).
LIGHTING
Lighting for reach-in door cases is pre-installed during the
manufacturing process. The light switch is located on the
outside of the case, underneath the front panel at the far
left-hand end. For any questions or service needs, please
contact our Case Division Customer Service Department
toll-free at 1-800-283-1109.
CASE CONNECTIONS
ATTENTION!
Be certain to clear the case of any loose
packaging or case materials before ener-
gizing the case. Failure to do so may re-
sult in case damage or malfunction.
ATTENTION!
Be certain that all piping and electrical
connections comply with local codes.
Fig. 13 "P" trap
"P"
TRAP
Fig. 15 Junction box beneath case
Fig. 14 Junction box beneath case