NTRODUCTION
C A U T I O N !
The instructions provided herein should
be completely reviewed and understood
prior to installing, operating or repairing
this equipment. All ATTENTION, CAU-
T
ION, DANGER and WARNING notes
must be strictly observed to prevent seri-
ous injury or equipment malfunction.
Scope
This manual includes installation,
operation and maintenance infor-
mation for 1.5 through 6.0-in.
Norriseal Series 1001, 1001A, and
1001XL Level Controllers.
Description
The Series 1001, 1001A, and 1001XL
Level Controllers are designed for
general purpose use in liquid level
and interface control applications
calling for either modulating
(Throttle) or on/off (Snap) pneumatic
service and can be direct or reverse
acting. Electric switch models are
also available.
Norriseal level controllers are
equipped standard with horizontal
or vertical PVC 1.88 x 12-in. displac-
ers. Displacer options include Acrylic
and 316L S.S. materials in various
lengths and diameters, including
hinged models, to accommodate a
wide range of control applications.
The 1001 has a smaller case than the
1001A or 1001XL and has a knurled
knob screw type closure. The 1001A
a
nd 1001XL have lever latch door
closing mechanisms and have a
sealed door. The 1001 and 1001A
have the case mounted left or right
of the body, while the 1001XL is cen-
ter-back mounted.
C A U T I O N !
Before disassembly or maintenance, all
pressures in this device must be relieved.
Failure to relieve pressures may result in
personal injury or device damage. The
resulting uncontrolled venting or spilling
of process uids may cause personal
injury, loss of process control or environ-
mental contamination.
Controller Identification
Controller model numbers are typi-
cally 13 positions long (example:
2SM60-SRDA-BG). Refer to Table 1
Model Designation on page 2 for
specific information on the controller
nomenclature.
A nameplate attached to the inside of
the case by the lower door hinge
includes the controller model and
serial numbers as well as other infor-
mation pertinent to the controller
assembly, such as supply and out-
put pressures, displacer material and
rating, body size and material, ANSI
class, and pressure and temperature
limits.
Always use only Norriseal replace-
ment parts when servicing level con-
trollers. Please refer to the serial and
model numbers when ordering
replacement parts.
Page 1 of 12
O
PERATING AND
M
AINTENANCE
M
ANUAL
Series 10 01, 10 01A, 1001XL Level Control
CONTENTS
P
AGE
I
NTRODUCTION
1
Scope 1
Description 1
C
ontroller Identification
1
P
RINCIPLE OF
O
PERATION
3
P
ILOT
O
PERATION
4
1.0 L
EVEL
C
ONTROLLER
I
NSTALLATION AND
S
TART
-
UP
5
1.0 L
E
VEL
A
D
JUSTMENT
6
1.2 L
IQUID
L
EVEL
I
NTERFACE
6
2.0 L
EVEL
C
ONTROLLER
M
AINTENANCE
7
2.1 L
EVEL
C
ONTROLLER
P
REVENTIVE
M
AINTENANCE
7
2.2 L
EVEL
C
ONTROLLER
D
ISASSEMBLY
7
2.3 L
EVEL
C
ONTROLLER
R
EASSEMBLY
7
2.4 P
ILOT
R
EMOVAL
/R
EPLACEMENT
8
2.5 L
EVEL
C
ONTROLLER
D
ISASSEMBLY
C
ASE
M
OUNTING
C
ONVERSION
9
2.6 L
EVEL
C
ONTROLLER
D
ISASSEMBLY
P
ILOT
A
CTION
C
ONVERSION
9
2.7 L
EVEL
C
ONTROLLER
B
ODY
D
ISASSEMBLY
9
2.8 L
EVEL
C
ONTROLLER
B
ODY
R
EASSEMBLY
9
3.0 R
EPAIR
K
ITS
10
T
ABLES
Table 1 Model Designation 2
Table 2 Wiring Diagrams 10
Tabla 3 Trouble Diagnosis 11
A
B
S
Q
u
a
l
i
t
y
E
v
a
l
u
a
t
i
o
n
s
,
I
n
c
.
M
a
n
a
g
e
m
e
n
t
S
y
s
t
e
m
C
e
r
t
i
f
i
c
a
t
i
o
n
Question and Answer IconNeed help?

Do you have a question about the Dover NORRISEAL 1001 Series and is the answer not in the manual?

Dover NORRISEAL 1001 Series Specifications

General IconGeneral
Series1001
CategoryControl Systems
ManufacturerDover
TypeLevel Controller
ApplicationIndustrial control and automation

Summary

Introduction

Scope

Manual covers installation, operation, and maintenance for Series 1001, 1001A, 1001XL Level Controllers.

Description

Details the purpose and features of Series 1001, 1001A, 1001XL Level Controllers.

Controller Identification

Explains how to identify controller models using nameplates and model numbers.

Principle of Operation

Force Balance Principle

Explains the core force balance principle used by the level controllers.

Adjusting Proportional Band

Describes how to adjust the proportional band by moving the fulcrum.

Adjusting Level

Details how to adjust the level by changing spring tension.

Pilot Operation

Snap, Relief, and Envirosave Pilots

Explains the operation of snap, relief, and envirosave pilots.

Throttle Pilot

Describes the operation of the throttle pilot, its seats, and pressure feedback.

Electric Pilot Switches

Outlines the available electric pilot switch types and configurations.

Level Controller Installation and Start-Up

Level Adjustment

Details steps for adjusting the level by turning the adjusting knob on the balance spring.

Liquid Level Interface

Explains how to set the sensitivity fulcrum and adjust spring tension for interface control.

Level Controller Maintenance

Preventive Maintenance

Outlines routine checks and replacement of O-rings and bearings.

Level Controller Disassembly

Provides steps to disassemble the controller, excluding the pilot.

Level Controller Reassembly

Details the procedure for reassembling the controller after disassembly.

Pilot Removal/Replacement

Instructions for removing and replacing pneumatic and electric pilots.

Case Mounting Conversion

Steps to convert the controller's case mounting configuration.

Pilot Action Conversion

Procedure to convert between snap and throttle pilot actions.

Body Disassembly

Instructions for disassembling the controller body and its components.

Body Reassembly

Steps for reassembling the controller body with new O-rings and backup rings.

Repair Kits

Lists available repair kits for controller maintenance.

Related product manuals