4. Push the Load button to show the data.
5. These reports can be exported to a csv format that can be saved in a spreadsheet or text editor. Click
the CSV Export button to continue.
Below are descriptions of the contents of each report:
HOURLY REPORT
This report will show (see the image above):
l The Loss rate in liters / hour up to that hour (cumulative figure).
l The volume, the level and the temperature at the end of the hour.
l The cumulative dispenser sales (field Sales) up to that hour.
l The difference in liters because of the temperature difference between the current hour and the hour
before.
l The difference in liters because of the evaporation between the current hour and the hour before (only
if an evaporation factor has been programmed in the ACR settings in the Tank Setup).
l The difference because of the water change in liters between the current hour and the hour before.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 71