EasyManua.ls Logo

Dover PSG WILDEN XPR460 - SECTION 5: Performance; XPR460 Metal Rubber-Fitted; XPR460 Metal Reduced-Stroke PTFE-Fitted

Dover PSG WILDEN XPR460
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WIL-11730-E-01 8
XPR460 Bolted Metal
SECTION 5
XPR460 METAL
RUBBER-FITTED
ShipWeight……….….Aluminum17.8kg(39.2lb)
316 Stainless Steel 28.8kg (63.4 lb)
Air Inlet……………………………………….3/4"
Inlet...………………………………38 mm (1.5")
Outlet………………………………38 mm (1.5")
Suction Lift………..…………..6.5 m Dry (21.3)
9 m Wet (29.5)
Disp. per Stroke
1
……………....1.0 L (0.29 gal)
Max. Flow Rate……...……...322 lpm (85 gpm)
Max. Size Solids…………………4.8mm(3/16'')
1
Displacement per stroke was calculated at 4.8
bar (70 psi) air inlet pressure against a 2.1 bar
(30 psi) head pressure.
Example: A PR460 metal rubber-fitted pump
achieved a flow rate of 178 lpm (47gpm)
using 64.6 Nm
3
/h (38scfm) of air when run at
4.1 bar (60 psi) air inlet pressure and 2 bar
(30 psi) discharge pressure.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psi) air supply pressure.
XPR460 METAL
REDUCED STROKE PTFE-
FITTED
ShipWeight……….….Aluminum17.8kg(39.2lb)
316 Stainless Steel 28.8kg (63.4 lb)
Air Inlet……………………………………….3/4"
Inlet...………………………………38 mm (1.5")
Outlet………………………………38 mm (1.5")
Suction Lift………..……………2.5 m Dry (8.2′)
9 m Wet (29.5′)
Disp. per Stroke
1
……………..0.56 L (0.15 gal)
Max. Flow Rate……...………337lpm (89 gpm)
Max. Size Solids…………………4.8mm(3/16'')
1
Displacement per stroke was calculated at 4.8
bar (70 psi) air inlet pressure against a 2.1 bar
(30 psi) head pressure.
Example: A PR460 metal reduced-stroke
PTFE-fitted pump achieved a flow rate of 182
lpm (48gpm) using 102 Nm
3
/h (60scfm) of air
when run at4.1 bar (60 psi) air inlet pressure
and 2.1 bar (30 psi) discharge pressure.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psi) air supply pressure.