EasyManua.ls Logo

DPM KY098YB User Manual

DPM KY098YB
32 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
KY098YB
Detektor drewna, metalu iprzewodów pod napięciem
Wood, metal and live AC wire detector Holz-, Metall- und
Leitungsnder
Детектор дерева, металла и проводов
Medienos, metalo
ir laidų detektorius Detektor dřeva, kovů avodičů Koka, metāla un
kabeļu detektors Puidu, metalli ja traadi detektor
Question and Answer IconNeed help?

Do you have a question about the DPM KY098YB and is the answer not in the manual?

DPM KY098YB Specifications

General IconGeneral
BrandDPM
ModelKY098YB
CategorySecurity Sensors
LanguageEnglish

Summary

Safety Instructions

User's Manual

User's manual is part of product, store with device.

Read Manual Before Use

Read manual & check specs before use.

Proper Operation

Improper operation may cause damage, fire, or hazards.

Manufacturer Liability

Manufacturer not liable for damages from improper use.

Device Inspection

Inspect device for damage before use; do not use if damaged.

Tampering Prohibition

Do not open/disassemble; repairs by authorized service center only.

Usage Environment

Use only in dry interior rooms; IP20 rated.

Temperature Acclimation

Allow device to reach room temperature after temp changes.

Protection Against Elements

Protect from dropping, heat, humidity, sunlight, chemicals.

Cleaning Instructions

Clean with dry, soft cloth; avoid abrasive cleaners.

Toy Prohibition

Product is not a toy; keep away from children and animals.

Features

Calibration

Select Detection Mode

Choose mode: AC WIRE, METAL, or STUD.

Detector Placement

Place detector parallel to wall for calibration.

Initiate Calibration

Press & hold ON/OFF switch to start calibration.

Calibration Completion

Calibration ends when audible signal stops.

Start Detection

Hold switch and begin detection after calibration.

Calibration Precautions

Avoid wet surfaces; check for live wire indicator ©; clear area.

Detection

Remove Metal Jewelry

Remove metal jewelry from hands before scanning.

Hand Placement

Hold detector with one hand; other hand >15cm away.

Repeat Measurements

Perform measurements multiple times for precision.

Weak Signal Handling

If signal is weak, try a different measurement location.

Electrostatic Phenomenon

Diode blinking may mean static charge; touch wall to discharge.

Battery Replacement

Install New Battery

Install new DC 9V battery before first use or when indicator is visible.