Pocket Guide
Evita® Innity V500
Software version 2.n
D-21865-2020

Other manuals for Dräger Evita Infinity V500

Question and Answer IconNeed help?

Do you have a question about the Dräger Evita Infinity V500 and is the answer not in the manual?

Dräger Evita Infinity V500 Specifications

General IconGeneral
BrandDräger
ModelEvita Infinity V500
CategoryMedical Equipment
LanguageEnglish

Summary

Intended Use

Evita V500 Ventilation Unit

Describes the Evita V500's purpose for adult, pediatric, and neonatal ventilation.

Infinity Medical Cockpit C700

Details the purpose of Medical Cockpits for monitoring and control in patient care.

System Overview

Intensive Care Ventilator

Overview of the complete Evita ® Infinity V500 intensive care ventilator system components.

Cockpit Front Panel

Identifies key components and controls on the front panel of the Infinity C500 cockpit.

Cockpit Back Panel

Details the ports and mounting options on the back panel of the Infinity C500 cockpit.

Ventilation Unit Front Panel

Highlights the front panel components of the Evita V500 ventilation unit.

Operating Concept

Main Screen Layout

Explains the layout and sections of the main operating screen.

Main Screen Elements

Details the various information fields and labels displayed on the main screen.

Alarm Priorities

Details the color coding and urgency of different alarm priorities.

Touch-Turn-Confirm Interaction

Describes the interaction method for selecting and setting parameters using controls.

Getting Started

Switching on Evita V500 and Infinity C500

Step-by-step guide for powering on the ventilation system and cockpit.

Selecting Breathing Circuit and Humidifier

Instructions for configuring the breathing circuit and humidifier settings.

Performing Device Check

Guide for executing the mandatory system check before patient use.

Performing Breathing Circuit Check

Steps to verify the proper function of the breathing circuit.

Selecting a Patient

Process for admitting a new patient and setting initial parameters.

Setting Ventilation by Patient Category

How to configure ventilation parameters based on patient category.

Selecting Tube or NIV Application Mode

Guidance on switching between non-invasive and tube ventilation modes.

Selecting Therapy Type

Instructions for choosing between Ventilation and O2 therapy modes.

Operation

Ventilation Settings Dialog

How to open and navigate the ventilation settings dialog.

Setting Ventilation Parameters

Detailed steps for adjusting specific ventilation parameters like RR.

Additional Ventilation Settings

Guide to combining ventilation modes with extra settings for optimization.

Switching on O₂ Therapy

Procedure for activating and using O2 therapy.

Ending Operation

Steps to properly shut down or put the Evita V500 into standby mode.

Alarms

Display of Optical Alarm Signals

How optical signals like the alarm bar and message fields indicate alarms.

Display of Acoustic Alarm Signals

How acoustic signals indicate alarms and how to silence them.

Displaying Current Alarms

Steps to view active alarms and acknowledge them.

Setting Alarm Limits

Instructions for configuring upper and lower alarm limit values.

Monitoring

Installing CO₂ Sensor and Cuvette

Guide for correctly connecting the CO2 sensor and cuvette.

Performing CO₂ Zero Calibration

Steps for calibrating the CO2 sensor for accurate measurements.