It should be equipped with a ltering device, con-
sisting of a sieve, air lter and oil level indicator. The oil
lter should allow removal of impurities with a maximum
size of approx. 250 microns (not shown in the diagram).
The operating volume of the tank should be at least 60
liters. NOTE! Do not ll the tank completely to allow room
for expansion. Use hydraulic oil, e.g. CastrolHyspin AWS
10, 15, 22, 32, 46, 68, 100, 150 or similar.
Should be as short as possible, hose connectors
should be compatible with the pump, tank and winch sock-
ets.
Provides better control over oil ow.
The oil cooler is responsible for maintaining the
operating temperature permissible for the type of oil
used.
DWHI 300 HD
DWHI 450 HD
DWHI 660 HD WINCHES
Connection diagram - see section B at the end of the man-
ual.
Open system with check valve.
The safety pressure relief
valve is mounted in the hydraulic block on the motor.
Maximum oil ow 60 l/min. The pump should pro-
vide a maximum pressure of 140 bar.
It should be equipped with a ltering device, con-
sisting of a sieve, air lter and oil level indicator.
The operating volume
of the tank should be at least 60 liters. NOTE! Do not ll
the tank completely to allow room for expansion. Use hy-
draulic oil, e.g. CastrolHyspin AWS 10, 15, 22, 32, 46, 68,
100, 150 or similar.
Should be as short as possible, hose connectors
should be compatible with the pump, tank and winch sock-
ets.
4-channel 4/3 distributor.
Provides better control over oil ow.
The oil lter is designed to remove impurities up
to approx. 250 microns.