DANGER, WARNING, CAUTION notes on gas, operation, and pressure.
Procedures for commissioning, heating, and error handling.
Steps for decommissioning and troubleshooting common errors.
Essential requirements before initial burner commissioning.
Detailed steps for preparing and commissioning the burner.
Adjusting the motorised air damper for maximum load conditions.
Procedures for setting the burner load and gas flow rate.
Adjusting the motorised air damper for minimum load conditions.
Explanation of the pneumatic gas/air ratio control system.
How the pneumatic gas/air ratio control system operates.
Steps for configuring the gas/air ratio control system.
Setting gas and air dampers using the servomotor.
Configuration of gas and oil pressure switches for safety.
Adjusting gas and air dampers for minimum load.
Steps for the initial start-up of the burner on the boiler.
Final checks before system handover.
Adjusting gas and air dampers for maximum load.
Adjusting the burner for optimal efficiency and behavior.
Adjusting gas and air volumes for optimal performance.
Ignition procedures for burners up to 7.5 MW.
Ignition for dual fuel burners up to 7.5 MW.
Methods for flame detection.
Description, technical data, and single-pole ignition.
Description, technical data, and two-pole ignition.
Table specifying nozzle bores for burner models.
Determining the correct nominal width for the gas ramp.
Procedure for performing a leakage test on the gas ramp.
Procedures for mounting the fan impeller with a fixed hub.
Procedures for dismantling the fan impeller with a fixed hub.
Voltage, frequency, temperature, and moisture specifications.
Important safety warning regarding electrical connections.
Safety warnings and compliance notes for wiring diagrams.
Explanation of the function of the gas pressure switch MIN.
Steps to configure the gas pressure switch MIN.
Explanation of the function of the gas pressure switch MAX.
Steps to configure the gas pressure switch MAX.
Explanation of the function of the air pressure switch.
Steps to configure the air pressure switch.
Allocation of electric motors for MONObloc burners up to 10.5 MW.
Allocation of electric motors for DUObloc burners up to 25 MW.
Explanation of the 'frequency' speed control system.
Allocation of motor speed to air damper position.
Description and uses of the quattro pro control unit.
How to operate the controller and its levels.
Configuring upper and lower setpoint limits for the controller.
Steps for configuring the controller with a pressure sensor.
Changing parameters using a pressure sensor.
Steps for configuring the controller with a temperature sensor.
Changing parameters in the parameter level.
Possible causes and troubleshooting steps for startup issues.
Troubleshooting steps for ignition-related issues.
Troubleshooting for burners shutting off after startup or errors.
Troubleshooting for flame ignition failures and output errors.
Troubleshooting intermittent operational errors.
Procedures for emission measurements and NOx corrections.
Checklist of essential maintenance tasks.
Guidelines for annual maintenance of safety-critical components.
Procedures and requirements for replacing safety-relevant components.