45167A
Printed in Canada 31-10-2013
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED
Manufactured by: Stove Builder International Inc.
250, rue de Copenhague, Saint-Augustin-de-Desmaures (Quebec) G3A 2H3
Tel: ( 418 ) 878-3040 Fax: ( 418 ) 878-3001
Warning: If your appliance is not properly installed a house fire may result. For your safety, follow the installation
directions. Contact local building or fire officials about restrictions and installation inspection requirements in
your area.
PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to
follow these instructions could result in property damage, bodily injury, or even death.
Save these instructions.
Some surfaces become hot at higher feeding rates. To prevent potential burns, avoid contact with those areas.
This heating appliance must serve as a supplementary heat source. An alternative heat source should be available
in the home if needed. The manufacturer cannot be responsible for additional heating costs associated with the
use of an alternative heat source.
It is highly recommended that the user buys this product from a retailer who can provide installation and
maintenance advice.
OWNER’S MANUAL
MODEL ECO-45
Thismanualisavailableforfreedownloadonthemanufacturer’swebsite.Itisacopyrighteddocument.Resaleisstrictly
prohibited.Themanufacturermayupdatethismanualfromtimetotimeandcannotberesponsibleforproblems,injuries,
ordamagesarisingoutoftheuseofinformationcontainedinanymanualobtainedfromunauthorizedsources.

Questions and Answers

  • M
    martinezgregoryAug 13, 2025
    What to do if Drolet ECO-45 feeds pellets but will not ignite?
    • J
      John LopezAug 13, 2025
      If your Drolet Pellet stove feeds pellets but won't ignite, it could be due to several factors: the air damper being open too far, a blockage in the igniter tube or its inlet, a faulty igniter element, a malfunctioning thermistor heat sensor, or the control board not sending power to the igniter. Try turning the air supply knob toward the minimum setting for startup. Remove the burn pot and clean it, ensuring all openings are clear, including the igniter tube. Check if the igniter element glows after applying power to it directly.
  • M
    Meagan BassAug 17, 2025
    Why my Drolet ECO-45 Pellet stove stops feeding pellets and shows on the control board?
    • R
      Ricky JonesAug 17, 2025
      If your Drolet Pellet stove stops feeding pellets, it may be because the L-250 manual reset high temperature switch has tripped. Locate the L-250 high temperature switch and press the red button on the back of it. If you hear a click, reset the stove. Inspect your unit, making sure the convection blower works and cleaning any dust off of its windings and blades.
  • S
    Scott BradleyAug 20, 2025
    Why does the auger motor on my Drolet ECO-45 stop feeding pellets and then start again?
    • D
      Deborah LiuAug 20, 2025
      The auger motor in your Drolet Pellet stove might be overheating, causing its internal temperature shutoff (thermal protector) to trip. Empty the hopper, remove the auger motor, and inspect the auger shaft for bent flights, burrs, or broken welds. Remove any foreign material and check the auger housing for damage. Clean the auger housing thoroughly to remove all pellet dust.
  • R
    Randy HendersonAug 25, 2025
    How to fix a Drolet ECO-45 when the control board doesn't display any information?
    • P
      Patricia GreenAug 25, 2025
      If the control board on your Drolet Pellet stove isn't displaying any information, a fuse on the control board may have blown. Remove the control board and check the F2 fuse on the back of it. If it appears to be bad, replace it with a 7.5 Amp 250 Volt fuse.
  • D
    Dawn GarciaAug 27, 2025
    Why does the glass soot up so fast on my Drolet ECO-45?
    • T
      Thomas ReedAug 28, 2025
      The glass on your Drolet Pellet stove might be sooting up quickly due to several reasons: a dirty stove or vent pipe restricting airflow, improper vent pipe installation, the air damper being closed too far, blocked burn pot holes, a blockage in the air intake pipe, the combustion/exhaust blower not spinning fast enough, or the use of bad pellets. Try cleaning the stove and vent pipe, adjusting the air damper, cleaning the burn pot, inspecting the air intake pipe, or using a different brand or type of pellets, ensuring they are dry and stored properly.
  • Y
    ysmithSep 4, 2025
    How to stop smoke smell coming back into my home from Drolet Pellet stove?
    • C
      Carl BrownSep 4, 2025
      If you're experiencing a smoke smell coming back into your home from your Drolet Pellet stove, it could be due to a leak in the vent pipe system or a bad gasket on the combustion/exhaust blower housing. Inspect all vent pipe connections to ensure they are properly sealed and fastened. Also, check the condition of the gasket on the combustion/exhaust blower housing.
  • Y
    Yesenia ChaneySep 8, 2025
    What to do if my Drolet ECO-45 feeds pellets but will not ignite after replacing the control board?
    • S
      sarah76Sep 8, 2025
      Remove the control board and check at the back to see if the F3 fuse appears to be bad. Replace it with a 5 Amp 250V fuse. Plug the stove back and try to run the unit.
  • C
    Cheryl BaileyDec 1, 2025
    What to do if my Drolet ECO-45 Pellet stove shuts off and displays on the control board?
    • M
      michelle50Dec 1, 2025
      If your Drolet Pellet stove shuts off, it could be due to several reasons: * A blocked airflow pressure switch hose or pressure tab. * Blockage in the air inlet, burn pot, combustion air chambers, combustion blower, or exhaust pipe. * Incorrectly installed vent pipe. * Faulty airflow pressure switch wire connections. * Loose airflow pressure switch wires. * Combustion/exhaust blower failure. * Control board malfunction. * Airflow pressure switch failure. Try unhooking the air hose from the airflow switch and blow through it to clear any blockages. Inspect the air inlet, burn pot, combustion air chambers, combustion blower, and exhaust pipe for blockages. Check the vent pipe installation. Ensure the airflow pressure switch wire connections are secure. If the combustion/exh...

Summary

Professional Installation Recommendation

Introduction to the ECO-45 Pellet Stove

Safety Precautions for Stove Operation

Installation Guide

Stove Specifications

Details about the ECO-45 Freestanding Pellet Stove's dimensions, weight, and capabilities.

Installation Preparation and Clearances

Steps for stove prep, assembly, and required distances from combustibles.

Combustion Air Supply and Venting

Vent Length and Installation Configurations

Vent Termination Location

Chimney Venting Systems

Masonry Chimney Venting

Optional Log Set Installation

Filters Installation and Cleaning

Operation Guide

Proper Fuel Selection

Guidelines on approved pellet fuels, types to avoid, and quality considerations.

Startup and Lighting Procedures

Steps for pre-start checks, building a fire, and initial lighting of the stove.

Unit Controls and Operating Modes

Stove Safety Features and Shutdown

Thermostat Installation

Operating Stove with Thermostat

How to connect and use a thermostat for automatic temperature control.

Thermostat Installation Location

Maintenance Procedures

Ash Removal and Disposal

Instructions for safely removing and disposing of ashes from the stove and ash bin.

Stove Cleaning Procedures

Details on cleaning heat exchanger tubes, baffles, chamber walls, and blowers.

Vacuum Use and Cleaning

Recommended Maintenance Schedule

Troubleshooting Guide

Troubleshooting: Stove Shuts Off (Code P)

Diagnoses and remedies for issues causing the stove to shut off with the 'P' error code.

Troubleshooting: Stove Shuts Off (Code E)

Diagnoses and remedies for issues causing the stove to shut off with the 'E' error code.

Stove Stops Feeding Pellets

Pellet Feed, No Ignition Troubleshooting

Stove Stops Pellet Feed Error Codes

Electrical Diagram

Replacement Parts List

Horizontal;Vertical Vent Chart

Inspection and Repair Form

Drolet Limited Lifetime Warranty

Drolet ECO-45 Specifications

General IconGeneral
Maximum Heat Output45, 000 BTU/h
Hopper Capacity60 lbs
ThermostatYes
Fuel TypePellet
Venting3" or 4"
WarrantyLimited lifetime