How to know if a lancet will fit with Droplet Genteel
Shape
Is the base of the lancet square?
Droplet Genteel was designed to
work with most square shaft lancets.
Fit
Does the lancet fit and stay in the
shuttle, even if you shake the device?
Size
Remove the Contact Tip from the Nozzle.
Hold Nozzle with the small side up. Drop
the lancet down through the Nozzle. Does
the lancet pass all the way through?
If your lancet does not pass these three tests, it will not work with
Droplet Genteel. However, passing these tests only means it will fit
into Droplet Genteel’s shuttle, but does not guarantee its overall
quality or that the needle size is uniform.
The Droplet Genteel lancing device works with Droplet Personal
Lancets. It is recommended that you use Droplet 30G Personal
Lancets with the Droplet Genteel lancing device.
The Droplet
®
Genteel
®
lancing device is used with disposable sterile
lancets to draw capillary blood from the fingertip or alternate sites
for blood glucose testing or other utilizing small amounts of blood.
The Droplet Genteel lancing device is for single patient use only.
Please read these instructions from beginning to end before using for
the first time. Retain this manual for future reference. In addition to reading
the instructions, watch the quick start video at www.mydropletgenteel.tips
lancing device
INSTRUCTIONS
FOR USE
Choosing the Contact Tip
The Droplet Genteel lancing device comes with 6 Contact Tips,
different in color and thickness. They range from #1/thickest (Blue)
through #6/Thinnest (Violet). These thickness differences allow you to
adjust the depth of penetration of the lancet. To minimize discomfort,
use the shallowest depth (thickest, lowest number) Contact Tip that
still produces the right amount of blood.
Droplet Genteel comes factory-installed with the Blue #1 Contact Tip.
This is the thickest Contact Tip and allows for the shallowest depth
penetration. We recommend that you try the Blue factory-installed
Contact Tip the first time you use Droplet Genteel. Changing the
Contact Tip to a higher number will allow a deeper puncture depth.
DeepestShallowest
Blue
1
Yellow
2
Green
3
Clear
4
Orange
5
Violet
6
Undercut
Body contact side
Activation Button
Shuttle
Push Cap
Hole in Activation Button
Lancet
This is NOT a Droplet Genteel part
Front End
Contact Tip
Nozzle
Droplet Genteel lancing device parts
If any of these items are missing, appear damaged,
or you have any concerns, please contact Customer
Service at info@mydroplet.com or call 1-877-660-1900.
Droplet Genteel lancing device
Your Droplet Genteel lancing device comes with:
6 Contact Tips
Setting up Droplet Genteel for use
The Droplet Genteel lancing device is designed for single
user only. Never share the lancing device or lancets. Using
the Droplet Genteel lancing device, any of its parts, or any
lancing device on multiple individuals may increase the risk
of inadvertent transmission of bloodborne pathogens.
We recommend that you wash your hands with soap and
water before and after handling the Droplet Genteel lancing
device to prevent the transfer of bloodborne viruses or
infectious agents.
Always use a new lancet for each test. Never reuse lancets.
Always follow the instructions provided with your meter
for blood glucose testing.
Do not store the Droplet Genteel lancing device in high
temperatures above 150°F/66°C, typical of the dashboard
of a car on a hot, sunny day with the windows rolled up.
See How to know if a lancet
will fit with Droplet Genteel
See Choosing the Contact Tip and
Installing the Contact Tip on the Nozzle
Droplet Genteel lancing device with
a Contact Tip on the Nozzle
A sterile lancet
Alcohol swab and/or tissue
to clean test site
!
!
1
2
3
Warnings
Precaution
Question and Answer IconNeed help?

Do you have a question about the Droplet Genteel and is the answer not in the manual?

Droplet Genteel Specifications

General IconGeneral
BrandDroplet
ModelGenteel
CategoryLaboratory Equipment
LanguageEnglish

Summary

Choosing the Contact Tip

Setting up Droplet Genteel for Use

Attaching Contact Tip and Lancet

Guides on attaching a contact tip and inserting a sterile lancet into the device.

Preparing the Test Site

Instructions for cleaning the test site with an alcohol swab or tissue.

Lancet Compatibility Check

Lancet Shape Verification

Confirms lancet base is square for proper fit.

Lancet Fit Security

Tests if lancet remains secure in the shuttle when device is shaken.

Lancet Size Passage

Verifies lancet fits through the nozzle opening smoothly.

Installing Contact Tip onto Nozzle

Testing from the Fingertip

Cock and Prime Device

Instructions on how to cock the lancing device and warnings about priming.

Insert and Remove Lancet

Steps for inserting a new lancet and removing its protective cap.

Removing the Lancet

Cock Device to Remove Lancet

Procedure to cock the device before removing the used lancet.

Dispose of Used Lancet

Guidance on safely removing and disposing of the used lancet into a sharps container.

Alternate Site Testing

Cleaning the Droplet Genteel Lancing Device

Surface Cleaning

Wipe device exterior with a clean damp cloth before each use.

Quick Internal Cleaning

Clean O-ring on piston assembly with finger to remove surface dirt.

Deep Internal Cleaning

Flush vacuum tube and piston assembly with warm water.