Do you have a question about the DSEGenset DSE8620 MKII and is the answer not in the manual?
Clarifies notation used within the publication for better understanding.
Defines technical terms and acronyms used throughout the manual.
Lists DSE publications and third-party documents referenced in the manual.
Specifies the operational temperature range for the module.
Details UL requirements for installation and components.
Provides specifications for the module's terminals and connections.
Outlines the electrical power supply requirements for the module.
Details specifications for voltage and frequency measurement.
Provides specifications for current measurement.
Details the specifications for digital and analogue inputs.
Details the specifications for various output types.
Lists and describes the different communication ports on the module.
Explains the usage of communication ports like USB, RS232, RS485, and Ethernet.
Explains how to use the USB slave port for PC configuration.
Explains how to use the USB host port for data logging.
Details the usage of the RS232 serial port and modem connection.
Details the usage of the RS485 serial port and MODBUS RTU diagnostics.
Details the functionality and usage of the Ethernet port.
Explains the use of Ethernet for Modbus TCP communication.
Details the use of Ethernet for SNMP monitoring.
Describes how to connect the module directly to a PC via Ethernet.
Explains connecting to a basic Ethernet network.
Details connecting to a company Ethernet infrastructure.
Explains how to connect the module to the internet.
Details the ECU port for J1939 engine communication.
Explains the DSENet port and available expansion modules.
Details the module's internal sounder specifications.
Details values for accumulated instrumentation like engine hours.
Provides physical dimensions, panel cutout, and mounting details.
Lists relevant industry standards and certifications the module complies with.
Lists enclosure classifications (IP and NEMA ratings).
Details how to connect external devices to the module.
Provides detailed descriptions of all module connections.
Describes connections for power, stop, and outputs.
Details connections for analogue sensors and CAN bus.
Describes connections for MPU, ECU, MSC, and DSENet.
Details output and sensing connections for the generator.
Details mains voltage and frequency sensing connections.
Explains connections for current transformers.
Details the wiring for digital inputs.
Explains the RS485 port wiring and configuration.
Details the RS232 port wiring and configuration.
Describes the USB slave connector for PC configuration.
Details the USB host connector for data logging.
Provides a typical wiring diagram for system setup.
Shows a wiring diagram for a 3-phase, 4-wire system with restricted earth fault.
Explains different earth system configurations.
Illustrates the typical connection of DSENet expansion modules.
Presents wiring diagrams for alternative system topologies.
Wiring diagram for single-phase, 2-wire with restricted earth fault.
Wiring diagram for single-phase, 2-wire without earth fault.
Wiring diagram for single-phase, 3-wire with restricted earth fault.
Wiring diagram for single-phase, 3-wire without earth fault.
Wiring diagram for single-phase, 3-wire with restricted earth fault.
Wiring diagram for single-phase, 3-wire without earth fault.
Wiring diagram for 2-phase, 3-wire with restricted earth fault.
Wiring diagram for 2-phase, 3-wire without earth fault.
Wiring diagram for 2-phase, 3-wire with restricted earth fault.
Wiring diagram for 2-phase, 3-wire without earth fault.
Wiring diagram for 3-phase, 3-wire Delta without earth fault.
Wiring diagram for 3-phase, 4-wire without earth fault.
Wiring diagram for 3-phase, 4-wire with restricted earth fault.
Wiring diagram for 3-phase, 4-wire with unrestricted earth fault.
Describes the functions of the front panel push buttons.
Explains how to navigate and view instrument pages on the LCD.
Details the status information displayed on the module.
Displays engine parameters measured or derived from inputs.
Displays electrical values of the generator.
Displays electrical values of the mains supply.
Shows measured values from expansion modules.
Provides information on connected DSE Intelligent Battery Chargers.
Explains how alarms are indicated and managed.
Details how to view and manage the module's event log.
Describes communication ports and their usage.
Details the RS232 serial port and modem connection.
Describes the RS485 serial port and MODBUS RTU diagnostics.
Explains the status of USB connections.
Details network settings and IP configuration for Ethernet.
Shows the status of DSENet communication lines.
Details the operation of the inbuilt exercise run scheduler.
Describes parameters editable from the front panel.
Displays values from the module's internal PLC editor.
Shows CAN information from external devices.
Addresses miscellaneous module settings.
Details data logging settings and USB eject procedure.
Provides module and firmware version information.
Explains how user-configurable LEDs indicate module status.
Provides a quick guide to the module's operation.
Step-by-step guide to starting the engine.
Step-by-step guide to stopping the engine.
Explains how to use the Stop/Reset mode for the module.
Details engine operation and sequences in Manual Mode.
Details the engine starting sequence in Manual Mode.
Explains engine operation in Manual Mode.
Details the engine stopping sequence in Manual Mode.
Explains automatic starting, stopping, and loading sequences.
Describes the waiting state in Automatic Mode.
Details the engine starting sequence in Automatic Mode.
Explains engine operation in Automatic Mode.
Describes how the generator is loaded in Automatic Mode.
Explains how the generator is unloaded in Automatic Mode.
Details the engine stopping sequence in Automatic Mode.
Explains the operation of the generator when disconnected from the mains.
Details generator operation when in parallel with the mains.
Details generator operation in fixed export or base load mode.
Explains different power control modes for parallel operation.
Details modes for controlling power based on frequency.
Details modes for controlling reactive power based on voltage.
Explains mains mode for peak lopping or shaving.
Details the operation of the inbuilt exercise run scheduler.
Describes scheduler behavior in Stop Mode.
Describes scheduler behavior in Manual Mode.
Describes scheduler behavior in Auto Mode.
Mentions selectable configurations for system setup.
Explains features for maintaining engine load and shedding loads.
Explains the dummy load control feature for maintaining engine load.
Details the load shedding control feature.
Explains how to send control commands via SMS.
Explains how alarms are indicated and managed.
Explains how indications are displayed on the module.
Details the various warning alarms and their causes.
Explains electrical trip alarms and their management.
Details shutdown alarms and their immediate effect.
Explains engine maintenance alarms and their reset procedures.
Details alarms related to mains decoupling during parallel operation.
Explains the over current alarm and its settings.
Describes the immediate warning for over current conditions.
Explains the IDMT alarm for thermal protection.
Explains the IDMT alarm for short circuit conditions.
Explains the IDMT alarm for earth fault conditions.
Shows default settings for IDMT tripping curves.
Explains how to access the main configuration editor.
Lists parameters available in the main configuration editor.
Allows configuration adjustments while the engine is running.
Lists parameters available in the running configuration editor.
Outlines essential pre-start checks for system setup.
Details the four steps for successful generator synchronisation.
Covers control aspects for synchronisation.
Explains how to connect and set up governors for synchronisation.
Explains how to connect and set up AVRs for synchronisation.
Explains metering checks for correct generator and mains measurements.
Verifies generator CT connections are on the correct phases.
Checks generator CT orientation for correct current flow.
Verifies mains CT connection is on the correct phase.
Checks mains CT orientation for correct current flow.
Notes that communications steps are not applicable to this module.
Describes checks to ensure correct synchronisation.
Details procedures for fault finding and tuning loadsharing.
Describes expected operation during loadsharing.
Explains generator operation in Mains Mode for loadsharing.
Explains generator operation in Generator Mode for loadsharing.
Guides on adjusting PID settings for power control.
Lists common starting symptoms and their remedies.
Lists common loading symptoms and their remedies.
Lists common alarm symptoms and their remedies.
Lists common communication symptoms and remedies.
Lists common instrument reading issues and remedies.
Lists common synchronising/load sharing issues and remedies.
Addresses miscellaneous fault finding scenarios.
Details broadcast CAN messages for J1939-75.
Details engine instrumentation broadcast messages.
Details diagnostic trouble codes and alarm conditions.
Information on purchasing replacement connector plugs.
Information on purchasing module fixing clips.
Information on purchasing module sealing gaskets.
Lists available DSENet expansion modules and their specifications.
Guidelines for the disposal of waste electrical and electronic equipment.
| Alternator Input Frequency | 3.5 Hz to 75 Hz |
|---|---|
| Operating Temperature Range | -30°C to +70°C |
| Storage Temperature Range | -40 °C to +85 °C |
| Number of configurable inputs | 8 |
| Number of configurable outputs | 6 |
| Operating Temperature | -30°C to +70°C |
| Battery Voltage Monitoring | Yes |
| Generator Monitoring Parameters | Voltage, Current, Frequency, Power |
| Display | LCD |
| Input Voltage | 8 V to 35 V DC |
| Communication Ports | USB, RS232, RS485, Ethernet |
| Protection Features | Overvoltage, Frequency |
| DC Supply | 8 V to 35 V Continuous |
| Alternator Input Range | 15 V to 300 V AC (Ph-N) |
| Magnetic Input Range | 0.5 V to 70 V |
| Magnetic Input Frequency | 10, 000 Hz (max) |
| Protection Rating | IP65 (Front) |
| Engine Monitoring Parameters | Oil Pressure, Coolant Temperature |
| Language Support | Multiple |
| Certifications | UL, CE |
| Monitoring | Extensive monitoring of engine, generator, and mains parameters |