DSI JET Series - User Manual

Default Icon
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DSI
JET User Guide
Data Sciences International
Bluetooth
®
Receiver
Data Sciences International
119 14
th
Street NW, Suite 100
St. Paul, MN 55112
Phone: +1 (651) 481-7400
US: +1 (800) 262-9687
Email: support@datasci.com
www.datasci.com

Questions and Answers

  • D
    Dawn FrankAug 4, 2025
    Why is the signal noisy from my DSI JET?
    • D
      Douglas MurrayAug 4, 2025
      If the signal from your DSI Laboratory Equipment is noisy, it might be due to several reasons: * An ECG or RIP lead may not be properly connected to the JET device. Ensure all connections are secure. * An ECG lead may not be making good contact with the electrode. Check these connections. * The electrode might not be adhering well to the animal. Check and reattach if necessary. * The electrode could be placed over an area with excessive muscle movement; relocate it if needed. * Some electrode wires might not be attached to the animal. Connect all leads, or short the excess leads together using two patches back to back. * The BP Antenna may not be close enough to the BP implant. Move the BP Antenna closer to the implant and secure its location.
  • J
    Jessica ChristianAug 11, 2025
    How to fix no signal from the DSI JET JET device?
    • R
      Rebecca DodsonAug 11, 2025
      If there is no signal from your DSI JET device, it could be due to a few reasons: * The battery may need to be recharged. Ensure the battery is fully charged. * The battery might not be correctly connected to the JET device. Verify and correct the battery connections. * The ECG or RIP leads may not be properly connected to the JET device. Check and correct these connections as needed.
  • J
    jennifer45Aug 19, 2025
    What to do if the DSI JET Laboratory Equipment JET RIP signal volume is low?
    • J
      Judy DuncanSep 12, 2025
      If you're experiencing a low volume signal from the JET RIP on your DSI Laboratory Equipment, consider the following: * The RIP bands might be out of position. Check their placement and adjust if necessary. * The gain setting could be too low. Increase the gain setting on the RIP Modules. * There might be debris in the module to cable connector. Remove any debris from the connection.
  • Z
    zbrownAug 27, 2025
    Why is the signal clipped from DSI JET JET RIP?
    • T
      Tammy ThompsonAug 27, 2025
      If you're getting a clipped signal from the JET RIP on your DSI Laboratory Equipment, it's likely that the gain setting is too high. Try decreasing the gain setting on the RIP Modules.

Summary

Theory of Operation

Specifications

JET Device and Receiver Specifications

Details JET device models, technical, mechanical, battery specs, and receiver specifications.

Lead Sets

Information on compatible lead sets for various JET device models.

Monitoring ECG with JET and a 3 Channel ECG Lead Set

To Instrument a Dog for Measurement

Electrode and Lead Attachment

Guides on preparing sites and attaching electrodes and leads to the animal.

Device Connection and Accessory Setup

Covers installing the JET device, connecting leads, and setting up BP/RIP accessories.

To De-instrument a Dog

Maintenance

To Charge the Battery

Step-by-step instructions for charging the JET device's lithium-ion battery.

Room Setup Recommendations

JET Bluetooth Receiver Location Recommendations

Guidelines for optimal placement and configuration of JET Bluetooth Receivers in an animal room.

Troubleshooting

Technical Support

DSI JET Series Specifications

General IconGeneral
BrandDSI
ModelJET Series
CategoryLaboratory Equipment
LanguageEnglish