Summary

INTRODUCTION & DESCRIPTION

1-1. Intended Use

Manual for qualified service personnel detailing fault isolation and parts ordering.

1-2. Centrifuge Description

Overview of the high-speed centrifuge's function, motor, and refrigeration system.

1-3. Centrifuge Accessories

Lists accessories provided with the centrifuge, including catalog numbers.

1-4. Centrifuge Warranty

Details the warranty policy for the centrifuge and its components.

1-5. Service Decontamination Policy

Procedure for servicing instruments used with radioactive or pathogenic materials.

INSTALLATION

2-1. Inspection

Instructions to inspect the centrifuge for shipping damage upon receipt.

2-2. Location Requirements

Guidelines for selecting a suitable operating location for proper air circulation and ambient temperature.

2-3. Electrical Requirements

Specifies the required power sources, voltage, frequency, and amperage.

2-4. Installation Procedures

Step-by-step instructions for installing the centrifuge at its operating location.

2-5. Rewiring and Wiring

Procedures for voltage/frequency conversion and permanent wiring.

2-6. Test Run Procedure

Steps to perform a test run after installation or rewiring.

OPERATION

3-1. Setting Centrifuge Power On

How to turn the centrifuge on and its initial state.

3-2. Opening the Chamber Door

Procedure for opening the centrifuge's chamber door.

3-3. Centrifuge Controls Description

Explains the functions of the control panel indicators, buttons, and dials.

3-4. Centrifuge Operation

Step-by-step guide for loading, balancing, and running the centrifuge.

3-5. Rotor Speed Temperature Compensation

Guidance on compensating for temperature differences based on rotor speed.

3-6. Prevent Sample Freezing

Advice on how to avoid sample freezing under specific operating conditions.

3-7. Rotor Precool Procedure

Procedure for precooling the rotor for temperature-sensitive samples.

3-8. Troubleshooting Guide

Table listing common problems, their causes, and suggested solutions.

3-9. Reducing Speed for Excess Load Mass

Formula and guidance for reducing rotor speed based on load mass.

SPECIFICATIONS

4-1. Centrifuge Specifications

Detailed technical specifications for the centrifuge's performance, dimensions, and electrical requirements.

Rotor Information Table

Table listing specifications for various compatible rotors, including speeds and capacities.

PRINTED CIRCUIT BOARDS and SCHEMATIC DIAGRAMS

Controller PCB Component Description

Lists components and their descriptions for the controller PCB.

CALIBRATION

6-1. Handling Printed Circuit Boards Safely

Safety guidelines for handling static-sensitive electronic components.

6-2. Calibration Sequence Importance

Explains the importance of performing calibration steps in a specific order.

6-3. Calibration Criteria and Locations

Specifies environmental conditions and locations for calibration adjustments.

6-4. Required Test Equipment

Lists the necessary tools and equipment for calibration.

Speed Control Potentiometer Calibration

Calibrates speed control for accurate rotor speed control.

Speed Indicator M101 Adjustment

Adjusts the full range of speed indication for accuracy.

Overspeed Detector Calibration

Adjusts overspeed detection circuitry for RUN mode disable.

Temperature Indicator M102 Calibration

Adjusts temperature indicator for zero and full scale indications.

Rotor Speed Temperature Differential Calibration

Compensates for temperature differential between rotor and chamber.

Temperature Control Set-Points Calibration

Establishes RUN and HOLD mode compressor set points.

Overtemperature Detection Calibration

Adjusts overtemperature set point to inhibit or disable RUN mode.

Timer Control Knob and Switches Adjustment

Adjusts mechanical settings of control knobs and switches.

Imbalance Detector Calibration

Calibrates the imbalance detector for proper shutdown.

Controller PCB Test Point Descriptions

Lists and describes test points on the controller PCB.

Controller PCB Potentiometer Adjustments

Details potentiometer adjustments for the controller PCB.

ILLUSTRATED PARTS

Front Assembly Illustration and Parts

Illustration of the centrifuge's front assembly with parts labeled and listed.

Right View Assembly Illustration and Parts

Illustration of the centrifuge's right side assembly with parts labeled and listed.

Rear Assembly Illustration and Parts

Illustration of the centrifuge's rear assembly with parts labeled and listed.

Motor Assembly Illustration and Parts

Illustration of the centrifuge's motor assembly with parts labeled and listed.

Door Interlock Assembly Illustration and Parts

Illustration of the door interlock assembly with parts labeled and listed.

TROUBLESHOOTING

11-1. Emergency Sample Recovery

Procedure for safely recovering samples during a power outage or malfunction.

11-2. General Troubleshooting

Information not yet available for general troubleshooting.

Du Pont Sorvall RC-5B Plus Specifications

General IconGeneral
TypeFloor Model Centrifuge
Maximum Speed20, 000 rpm
Timer0-99 minutes, continuous
Drive SystemDirect drive
Refrigeration SystemCFC-free
Power Requirements208-230 V, 60 Hz, 30 A