Cooling Capacity | 36, 000 BTU/h |
---|---|
Refrigerant Type | R-410A |
Tonnage | 3 tons |
Voltage | 208/230V |
Operating Temperature Range (Cooling) | Up to 115°F |
Clean joints, use dry nitrogen, debur tube, use swage fitting, apply heat absorbing paste, braze, quench.
Check lines and coil after brazing and before evacuation using trace refrigerant and dry nitrogen.
Units are factory pre-charged for 15 ft. tubing. Avoid releasing refrigerant to atmosphere.
Turn off power. Check local codes, NEC for wire size. Provide ground. Power supply must agree with nameplate.
Units factory charged for 15 ft. line set. Adjust charge for line set length and evaporator coil.
Operate unit, measure pressure/temp at vapor valve. Calculate superheat. Adjust charge based on superheat.
Operate unit, measure pressure/temp at liquid valve. Calculate subcooling. Adjust charge based on subcooling.