Model: D2000iS
Inverter Generator
OPERATOR’S MANUAL
SAVE THIS MANUAL FOR FUTURE REFERENCE
This manual contains important information regarding safety
, operation, and maintenance.

Questions and Answers

  • M
    Michael GarzaAug 2, 2025
    Why is my Ducar D2000iS Inverter generator running but not supplying power?
    • I
      Ian McdanielAug 2, 2025
      Your Ducar Inverter generator might be running but not supplying power due to several reasons: * The DC Circuit Breaker might be in the “OFF” position. If so, turn the DC Circuit Breaker to the “ON” position. * The Green AC Pilot Light Indicator might be off, in which case you should stop the engine and restart it. * There might be a poor connection or a defective cord set, so check and repair them. * The connected device could be faulty; try connecting a device that is working properly. * There could be a fault in the generator, in which case you should contact the service department.
  • A
    Alicia DennisAug 7, 2025
    What to do if my Ducar D2000iS engine will not start, shuts down during operation, or starts and runs rough?
    • J
      jamesmolinaAug 8, 2025
      If your Ducar Inverter engine won't start, shuts down, or runs rough, consider these potential causes: * The 3 in 1 switch may be set to “OFF”. If so, turn the switch to “CHOKE” then pull the recoil starter. * The fuel may be stale or the unit may be out of fuel, in which case you should replace the fuel. * The spark plug wire may be disconnected from the spark plug; reconnect it. * The spark plug may be bad; clean or replace it. * There may be water in the fuel; drain the fuel tank and replace the fuel. * The engine may be overchoking; turn off the choke. * The oil level may be low; add oil. * There may be a faulty ignition, in which case you should contact our dealer.
  • T
    todd76Aug 14, 2025
    What to do if Ducar D2000iS engine runs good without load but bogs down when loads are connected?
    • T
      tbuchananAug 14, 2025
      If your Ducar Inverter engine runs well without a load but bogs down when loads are connected, it could be due to: * A short circuit in the connected device. Disconnect the device. * The generator being overloaded. See pg 17 “Don’t overload generator”. * The engine speed being too slow or a short circuit in the generator, in which case you should contact the service department.
  • R
    Rose JohnsonAug 21, 2025
    Why Ducar Inverter engine lacks power?
    • J
      Jeremy BruceAug 21, 2025
      Your Ducar Inverter engine may lack power because: * The generator is overloaded. See pg 17 “Don’t overload generator”. * The engine needs servicing, in which case you should contact the service department.
  • S
    Susan SmithAug 27, 2025
    How to fix Ducar D2000iS Inverter engine that “hunts” or falters?
    • P
      phamjanetAug 27, 2025
      If your Ducar Inverter engine “hunts” or falters, it might be because: * The choke was removed too soon. Move to choke until engine runs evenly. * The carburetor is running too rich or too lean, in which case you should contact the service department.

Summary

Safety Rules

Safety Symbols

Explains the meaning of warning and caution symbols used in the manual.

Safety Instructions

Provides general safety guidelines and warnings before operating the generator.

Control Panel Functions

Start Switch and Choke Operation

Explains the operation of the 3-in-1 Start Switch for starting and stopping the engine.

Control Panel Functions

Ground Terminal

Instructions on connecting the generator to a ground source for electrical safety.

Assembly

Assembly

Adding and Checking Engine Oil

Details the procedure for adding or checking the engine oil level for proper operation.

Operation

Dont Overload Generator

Guidance on selecting and connecting loads to avoid generator overload and damage.

How to Start Engine

Step-by-step instructions for starting the generator engine correctly.

Operation

Maintenance

Maintenance Schedule

Outlines regular maintenance tasks and their recommended intervals for optimal performance.

Changing Engine Oil

Step-by-step guide for draining and refilling the engine oil.

Maintenance

Troubleshooting

No Power Supply

Lists common causes and solutions when the generator runs but has no output.

Engine Bogs Down Under Load

Explains why the engine bogs down under load and provides solutions.

Engine Starting or Running Issues

Covers issues with starting, running, or shutting down the engine.

Wiring Diagram

Ducar D2000iS Specifications

General IconGeneral
Displacement79.7 cc
AC Voltage230V
DC Output12V / 8.3A
Output Voltage230V
Frequency50 Hz
TypeInverter Generator
Rated Power1.6 kW
Max Power2.0 kW
Engine Type4-stroke, OHV
Noise Level58 dB(A) at 7m
Rated AC Output1.6 kVA
Peak AC Output2000W
Protection FeaturesOverload, low oil
CoolingAir Cooled