D-LX 100
All-In-One
Flame Scanner
European
Standard
EN 230: 1991
Gas appliance
directive
90/396/EWG
Pressure equipment
directive
97/23/EG
Fuel Oil Gas Oil + Gas
Register Number: 5F161/03 CE-0085AT0397 BAF MUC 03 04 072357 003
Tested by TÜV Süddeutschland
Approved for intermittent operation, continuous operation and 72-hour operation.
Registered by DVGW and DIN CERTCO
American Standard: UL 372 FM Class 7610
Registration Number: MH25226 3000072 and 3010410

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the DURAG D-LX 100 and is the answer not in the manual?

DURAG D-LX 100 Specifications

General IconGeneral
BrandDURAG
ModelD-LX 100
CategoryScanner
LanguageEnglish

Summary

General Information

Block Diagram

Functional Description

Self-Check

Fault

Error Codes of the 1st CPU

Lists error codes, sources, and possible causes indicated by the yellow LED for troubleshooting.

Installation

Start-Up

Instructions for initial operation of the flame scanner after proper mounting and connection.

Programming the Flame Scanner

Setting the Flame Recognition Threshold

How to adjust the threshold to determine flame ON/OFF signals based on flame signal intensity.

Flame Recognition Thresholds as a Function of the Rocker Switch Setting

Table and graph detailing thresholds for different rocker switch positions.

Setting the Amplification

Adjusting signal amplification of the photo element for intense flame signals.

Adjusting the Flame Scanner D-LX 100...94Ex and D-LX 100.../95Ex

Procedures for programming explosion-proof models in hazardous environments.

D-ZS 087-20 Digital Display Unit

Using the digital display unit for optimal alignment and setting of flame recognition thresholds.

Safety Time

Integrated Flame Scanner

Ultraviolet Flame Scanner

Describes UV scanner types, spectral sensitivity, and suitability for gas/oil flames.

Infrared Flame Scanner

Explains IR scanner types, spectral sensitivity, and applications for oil/wood/coal flames.

Selection Criteria for the D-LX 100 All-In-One Flame Scanner

Criteria for selecting the appropriate flame scanner model based on fuel type and characteristics.

Overview of D-LX 100 All-In-One Flame Scanner

Lists different D-LX 100 models with various axial plug connections and flameproof housings.

Options

Details available options such as current output and safety time settings.

Technical Data

Technical Data of the Integrated Flame Scanner

Provides optical angle of view and spectral sensitivity data for various scanner models.

Technical Data and Configuration of Inputs and Outputs

Details power supply, fuse protection, current output, and relay contact specifications.

D-LX 100 Dimensional Drawing

Shows physical dimensions, connections, and viewing angles of the D-LX 100.

D-LX 100 Wiring Diagram

Illustrates the electrical connections for the standard D-LX 100 models.

D-LX 100 ... /94 Ex and D-LX 100.../95Ex Housing for Hazardous Areas

Provides dimensional drawings and technical data for explosion-proof housings.

Wiring Diagram for D-LX 100.../94Ex and D-LX 100.../95Ex

Shows wiring diagrams for D-LX 100 models with explosion-proof housings.

D-LX 100 ... /96 Ex for Hazardous Areas Class I, Div. 2, Group A,B,C&D

Details dimensional drawing and specifications for Class I, Div. 2 hazardous area use.

D-LX 100 ... /97 Ex for Hazardous Areas Zone 2

Provides dimensional drawing and specifications for Zone 2 hazardous area use.

Cable and Shielding

Guidelines on proper cabling, shielding, and error suppression for the D-LX 100.

Maintenance and Service

Replacement of the Shutter and the UV-Photocell on the D-LX 100 UL

Step-by-step guide for replacing the shutter and UV-photocell assembly.

Available Accessories

D-ZS 087-20 Digital Display

Describes the digital display unit for orientation, measurements, and threshold calculation.

D-NG 24/05 AC-Power Supply

Technical specifications for the AC-DC power supply unit for the flame scanners.

D-ZS 033-I Ball Type Adjustment Flange

Dimensional drawing and material details for a ball joint flange accessory.

D-ZS 033-III Ball Type Adjustment Flange

Dimensional drawing and material details for another ball joint flange accessory.

Weather Protection Hood

Description and dimensions of a weather protection hood for outdoor installations.

Approvals

DIN-CERTCO

Certificate details from DIN-CERTCO confirming conformity with EN 230.

EC Gas Appliance Directive 90/396/EC

EC type examination certificate for gas appliance directive compliance.

EC Pressure Equipment Directive 97/23/EC

Certificate details regarding compliance with the Pressure Equipment Directive.

UL-Listing

UL recognition for controls and primary safety components.

CUL-Listing

Canadian UL recognition for controls and primary safety components.

FM-Listing

FM approval details for various DURAG flame monitor systems and sensors.

ATEX Certificate

EC type-examination certificate for equipment used in potentially explosive atmospheres.

EC Declaration of Conformity

Declaration confirming product compliance with various Council Directives and standards.

Related product manuals