Instruction Manual
The DuraTrax
®
FlashPoint
Temperature Gauge is a
non-contact infrared thermometer. Specifically
designed for use with R/C engines, batteries, motors,
sealing irons and heat guns, simply aim the
temperature gauge at the target and press the
measurement button to quickly and easily display the
surface temperature! The distance to target ratio is
1:1, and therefore the temperature gauge should be
positioned as close to the target as possible.
Temperature Range: -27 to +428 degrees F
[-33 to +220°C]
Display Resolution: 0.1°F or C (switchable)
Response Time: 1 second
Infrared Accuracy: +/- 2% of reading
Field of View: 1:1 optics ratio
Emissivity: 0.95 default - adjustable
0.01 to
1 emissivity
Battery Life: 40 hours continuous use
(auto power off after 15
seconds)
Battery Type: CR2032 lithium primary
(not rechargeable)
Display Type: custom LCD
Dimensions: 0.7 x 1.5 x 2.7"
[18 x 37 x 68mm]
Weight: 1.13 oz. including battery [32g]
Push-button start
Extremely small and lightweight, for easy
portability anywhere.
Reads temperatures in degrees Fahrenheit (F)
or Celsius (C).
Very wide temperature range of -27 to +428
degrees F [-33 to +220°C].
Large, custom designed LCD for easy viewing and
a built-in battery power indicator.
Fast 1 second response time.
Highly accurate to within +/-2% of reading.
Easy push-button control of setup and measurement.
Includes a 15 second auto-off timer to prevent
accidental draining of battery.
Common non-rechargeable lithium battery included.
Handy wrist-strap included.
Electromagnetic / Radio Frequency
Interference:
Readings may be affected if the unit is operated
within a radio frequency electromagnetic field
strength of approximately 3 volts per meter, but
the performance of the instrument will not be
permanently affected. Keep this gauge at least 6
inches away from R/C transmitters to avoid radio
frequency interference.
Avoid keeping the temperature gauge too close
for long periods of time to objects that
continuously
generate high heat (like a hot plate), which can
cause overheating of the temperature gauge.
Do not allow water or moisture to come in contact
with the gauge.
Do not replace the battery with one other than a
“CR2032 lithium” non-rechargeable battery.
Sometimes it is easier to accurately measure the
temperature of an object by physically attaching a
thermometer or thermocouple to it. However, it can
often be difficult or inconvenient to do so.
Sometimes, it is only necessary to see the large
heat patterns of an object, rather than measuring
a temperature at a very precise location on the
device. In these cases, measuring an object’s heat
radiation with an infrared temperature gauge is a
good solution.
To get started using the FlashPoint Infrared
Temperature Gauge, first press the large
“MEASURE” button. The first display will show the
unit of measure of “°F” for fahrenheit or “°C” for
celsius. Follow these steps to change the unit of
measure, to adjust other settings, or to begin
measuring temperatures:
SETTING ADJUSTMENTS & TAKING
TEMPERATURE MEASUREMENTS
IMPORTANT PRECAUTIONS
SPECIAL FEATURES
SPECIFICATIONS
®
FlashPoint
Infrared
Temperature Gauge
Question and Answer IconNeed help?

Do you have a question about the Duratrax FlashPoint and is the answer not in the manual?

Duratrax FlashPoint Specifications

General IconGeneral
Distance to Spot Ratio8:1
Emissivity0.95 fixed
Laser PointerYes
Resolution0.1°F/°C
Auto Shut-offYes
Accuracy+/- 4°F (+/- 2°C)
Power9V battery
Units°F or °C
Laser TypeClass II
DisplayLCD
Weight5.6 oz
Dimensions6.3 x 3.1 x 1.6 in (160 x 80 x 40mm)

Summary

Specifications and Precautions

Specifications

Details technical specifications of the infrared temperature gauge, including range, accuracy, and battery life.

Important Precautions

Lists critical safety and usage warnings, including interference, heat exposure, and battery type.

Using the FlashPoint Temperature Gauge

Setting Adjustments and Measurements

Explains how to set units, adjust settings, and take temperature measurements with the device.

Fahrenheit or Celsius Unit Selection

Guides on how to switch the temperature unit display between Fahrenheit and Celsius.

Measuring Temperatures

Details methods for taking instantaneous and continuous temperature readings.

Storing Minimum and Maximum Temperatures

Explains how to temporarily store the minimum or maximum temperature observed.

Timer Lockout Mode

Describes how to disable the automatic shut-off timer for continuous operation.

Measuring Tips for Accuracy

Provides advice on how to achieve the most accurate temperature readings.

Advanced Features and Troubleshooting

Applications for R/C Usage

Suggests common R/C equipment applications for the temperature gauge.

Emissivity Adjustment

Explains emissivity and how to adjust it for more accurate readings on different materials.

LCD Error Messages

Details common error codes displayed on the LCD and their meanings.

Maintenance and Support

On-Screen Battery Indicator

Describes the battery power indicator and its meanings.

Battery Replacement

Provides instructions on how to replace the device's battery.

Wrist Strap & Belt Clip

Instructions on attaching the wrist strap and using the belt clip for portability.

Storage & Cleaning

Guidance on proper storage conditions and cleaning methods for the gauge.

Warranty Information

Details the product's warranty period, coverage, and void conditions.