Questions and Answers

  • B
    Brady HolderNov 11, 2025
    Why is there water in my DV Systems Dehumidifier?
    • K
      Karen Frye DDSNov 11, 2025
      There are several potential reasons for water in your DV Systems Dehumidifier. It could be due to a lack of power, so ensure the power line is active. Check the cabling and replace it if necessary. The electronic control board might be faulty, requiring inspection and potential replacement. Also, verify that the dryer is turned on and has been running for at least two minutes after start-up. Inspect the compressed air inlet/outlet connections to confirm they are properly connected. If the condenser is dirty, clean it. Finally, a malfunctioning condensate drain may be the culprit, so clean the condensate drainage system pre-filter. It can also be caused by the flow rate and/or temperature of the air entering the dryer are higher than the nominal values or the ambient temperature is higher t...
  • D
    Dr. Keith CollinsNov 20, 2025
    What to do if my DV Systems Dehumidifier has water inside?
    • P
      patrickwilliamsNov 20, 2025
      If you find water inside your DV Systems Dehumidifier, start by checking the power line and restoring power if needed. Inspect the cabling for issues and replace if necessary. Examine the electronic control board, replacing it if problems persist. Ensure the dryer is on and has been running for at least 2 minutes. Check that the compressed air inlet/outlet are correctly connected. Clean the condenser, and inspect/clean the condensate drainage system pre-filter. If the coil of the drainage solenoid valve is burned, replace it. Clean or replace the drainage solenoid valve if clogged or jammed. Check the C8 and C9 parameters of the electronic control board and replace it if the trouble persists. Check the probe and replace it if the trouble persists. Also, restore the nominal conditions if th...
  • M
    Melissa BarberDec 1, 2025
    How to fix water accumulating in DV Systems Dehumidifier?
    • R
      Richard JimenezDec 1, 2025
      To address water accumulation in your DV Systems Dehumidifier, begin by ensuring the unit is receiving power. Next, inspect the cabling for any damage and replace if needed. Check the electronic control board. Verify the dryer is powered on and has been running for at least 2 minutes. Confirm the compressed air inlet/outlet are correctly connected. Clean the condenser to ensure proper function. Clean the condensate drainage system pre-filter. Replace the coil of the drainage solenoid valve if burned. Clean or replace the drainage solenoid valve if clogged/jammed. Check the C8 and C9 parameters of the electronic control board and replace it if the trouble persists. Check the temperature control probe; if the trouble persists, replace it. Restore the nominal conditions if the flow rate and/o...