PROBLEMS SOLUTIONS
Add salt” is displayed Make sure that the equipment is connected to power supply and that the
electric card connector is inserted (vedi paragrafo 7.1)
Add salt” is displayed but salt is actually Clean the electrodes (see paragraph 10.1 steps 7 and 8). Check that the
present in the brine tank and water level
water level in the brine tank is above the salt grid (Image 1, F). If water level
is not too high is not too low, increase the B7 value in the EXTRA-RINSE (see paragraph
5.5)
Add salt” is displayed but salt is actually
Clean the ejector and its filter (see paragraph 10.1 steps 4 and 5). Check that
present in the brine tank and water level the drain pipe is not sqeezed or clogged. Check that the softener can suck
is too high water from the brine tank.
The valve does not regenerate automatically make sure that the equipment is connected to power supply (fig. 10, A, B)
and that the electric card connector is inserted (fig. 8, C). Check that “F00”
is not displayed (see paragraph 5.2.2)
The valve regenerates at the wrong time check the current time and regeneration time settings (see paragraph 4.2
and 5.3)
Water from the brine is not sucked - make sure that the water system pressure is at least 2 bar
the water softener does not consume salt - check that the drain pipe is not blocked or flattened (fig. 6, A)
(there will be a salt alarm) - clean the injector (fig. 11, B) (see paragraph 10.1)
-
make sure that there is no air intake where there are the quick joints (fig. 13, A)
The brine overfills:
- If the excessive filling occurs during - make sure the drain pipe isn’t blocked or flattened (fig. 6, A)
the regeneration
-
make sure that there is no air intake where there are the quick joints (fig. 13,
A)
(there will be a salt alarm) - clean the injector (fig. 11, B) (see paragraph 10.1)
- check that operating pressure is at least 2 bar
- make sure the selected model is correct
-
In case the refill time has been changed to include extra-rinse,make sure that
the duration of step B7 falls between the range values (see paragraph 5.5)
- If the excessive filling occurs when -
make sure there are no leaks between upper part and tank (fig. 1, C and D)
the machine is operating -
make sure water does not seep in the brine tank from the brine pipe (fig. 13, A)
Water softener salt consumption make sure the selected model is correct (see paragraph 5.4). In case the
is higher or lower than expected refill time has been changed to include extra-rinse,make sure that the dura-
tion of step B7 falls between the range values (see paragraph 5.5)
After regeneration, water is not softened - Check salt presence in the brine tank, in case the salt alarm is not on (see
paragraphs 5.6 and 5.7.2).
- Check correct start of the mixing screw, in case the salt alarm is on. (ima-
ge 3, M) (see paragraph 8)
The water softener dispenses salt water:
- If it only happens once his problem may be caused by a lack of hydric pressure during the rege-
neration, thus preventi correct rinsing, Start the resin rinse program (see
paragraph 7.4)
- If it is a recurring problem Increase by some minutes the B5 time in the EXTRA-RINSE (see paragraph
5.5, TAB. 3)
The anti-flooding device intervened - make sure that the water system pressure is at least 2 bar
to block the excessive flow of water - check that the drain pipe is not blocked and does not have too narrow
elbows that
in the brine tank flattening the pipe (fig. 6, A)
- clean the injector (fig. 11, B) (see par. 10.1, “PERIODIC MAINTENANCE”)
-
make sure that there is no air intake where there are the quick joints (fig. 13, A)