What to do if DWT BWT PERMAQ Pico 10-90 shows 'A1 Inlet pressure low'?
- TTrevor RoseAug 6, 2025
If you're seeing an 'A1 Inlet pressure low' error on your DWT Water Filtration System, it could be due to several reasons. The raw water inlet pressure might be too low, or the water supply could be interrupted. There might be water leakage, or the pre-filter may be blocked. Rapid pressure changes could also be a factor. It's also possible that the pressure switch is either not connected properly or is defective, or the raw water solenoid valve is defective. To resolve this: * Check the inlet pressure and ensure the water supply isn't affected. * Seal any water leaks. * Replace the pre-filter. * Eliminate pressure fluctuations. * Have qualified personnel check the connection at the appropriate terminal to P21.01. * Replace the pressure switch.