Example for Application
rain detector*
external control*
ventilation drive*
vent button*
* optional function extension (separate components retrofitable)
Safety notes
Operating voltage 230 V AC!
Risk of injury from electric shock!
Connection must be carried out by a certified electrical technician.
- Use only in dry rooms.
- Do not lay 24 V DC and 230 V AC cables in the same cable duct!
- Use unmodified original parts only.
- Observe the drive instructions for use.
Intended use
- Compact ventilation control for separate rooms and conservatories
- For triggering of 24 VDC drives
- 1 ventilation group
- 1 A total actuating current
- Ventilation safety function (key operation OPEN/CLOSE)
- Possibility of connecting rain detector or wind/ rain detector
- For installation in branch box provided on site
- Only for inside mounting
Technical Data
Type : PS-24-1-U
Power supply : 230 V AC 50 Hz
Power : 30 VA
Class of rating : short-time duty, 20%
Output : 24 V DC, max. 1 A
Ripple : <= 1%
Ingress protection : IP 30
Temp. range : -0 ... +50 °C
Housing : plastic
Dimensions : 50 x 48 x 28 mm WxHxD
Disposal
Electrical devices, accessories, batteries and packaging should be sorted for
environmental-friendly recycling.
Do not dispose electrical devices and batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for waste electrical and
electronic equipment and its implementation into national right, electrcal
devices that are no longer usable must be collected separately and dispo-
sed of in an environmentally correct manner.
PS-24-1-U
X2
N
b
IN:
230V
AC / 30V
A
OUT:
24VDC /
1A
2
mA
max.
50
IP 3030.241.61
Temp.: 0°C...+55°C
C
3
4
5
6
7
1
L
X1
24V
a
Power
supply
WARNING
Read all safety warnings, instructions, illustrations and specifications
provided with this product.
Failure to follow all instructions listed below may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
Maintenance and cleaning
Maintenance work is only allowed when the device is in a de-energized
condition! Inspection and maintenance has to be carried out according to D+H
maintenance notes. Only original D+H spare parts may be used. Repair is to be
carried out exclusively by D+H.
Wipe away debris or contamination with a dry, soft cloth.
Do not use cleaning agents or solvents.
PS-24-1-U
X2
N
b
IN:
230V
AC / 30VA
OUT
:
24VDC /
1A
2
mA
max.
50
IP 3030.241.61
Temp.: 0°C...+55°C
C
3
4
5
6
7
1
L
X1
24V
a
Power
supply
Question and Answer IconNeed help?

Do you have a question about the Dyer PS-24-1-U and is the answer not in the manual?

Summary

General Safety Warnings

Intended Use

Safety Notes

Technical Data

Maintenance and Cleaning

Disposal Instructions

Connection Diagrams

Basic Connection with BMS Interface

Diagram illustrating a basic connection with a BMS interface for the PS-24-1-U unit, showing power supply and signal inputs.

Overall Group Operation

Diagram showing multiple PS-24-1-U units configured for overall group operation, including connections for drives and switches.

Individual Control with Rain Sensor Override

Diagram for individual window control with a group rain sensor override, detailing connections for switches and rain sensors.