Section I. Installation Instructions
1) Turn the thermostat fan switch to the “OFF” position.
2) Turn off power to the furnace/air handler.
3) Remove the existing filter from the furnace/air handler or return air grille.
4) Wiring to the on-board transformer or integrated furnace control:
NOTE: ONLY A QUALIFIED ELECTRICIAN SHOULD PERFORM ELECTRICAL WIRING.
If there is a terminal strip such as the one shown in figure 1, connect the black wire of the power
cord to the “Common” terminal (typically the "C" terminal) and the black wire with the white stripe
to the “Hot” 24vac terminal (typically the "R" terminal). Output from the 24vac transformer may
vary due to local line voltage fluctuations. Outputs up to 28vac are acceptable.
Figure 1
If the terminals are unmarked, or to confirm the markings, use a voltmeter to find the Common
and “Hot” 24vac terminals:
a. Turn off the power to the furnace/air handler and the transformer.
b. With the voltmeter set to "Continuity", check for continuity between each terminal and the
metal frame of the furnace/air handler. Choose a spot on the furnace/air handler such as
a screw or unpainted edge, where a good electrical contact can be found.
c. If continuity is found between one of the terminals and the furnace/air handler, that
terminal will be the Common terminal.
d. With the power on to the transformer, use the voltmeter to locate the 24vac terminal.
Question and Answer IconNeed help?

Do you have a question about the Dynamic Polarized-Media and is the answer not in the manual?

Dynamic Polarized-Media Specifications

General IconGeneral
BrandDynamic
ModelPolarized-Media
CategoryAir Cleaner
LanguageEnglish

Summary

Installation Instructions

Wiring to Transformer or Furnace Control

Connect the power cord to the 'Common' and 'Hot' 24vac terminals on the terminal strip.

Identifying Common and 24vac Terminals

Use a voltmeter to locate the Common and 'Hot' 24vac terminals if unmarked.

Routing the Power Cord

Route the power cord through the cabinet, ensuring no crimping or abrasion, with adequate slack.

Optional Plug-In Transformer

Maintenance and Media Pad Replacement

Media Pad Replacement Procedure

Steps for removing the old media pad, cleaning the air cleaner, and installing a new media pad.

Media Pad Lifespan and Inspection

Media pads last 3-4 months; inspect after one month for new installations.

Replacement Parts

Ordering Replacement Media Pads