F 36
F_PL1000RS_GB.fm 36-76 - 04.07
Angular gear
Oil level check
$
Check oil level every 50 operating hours.
When checking the oil level or topping
the oil up, the machine must be standing
on level ground.
- Unscrew and remove the filler and in-
spection screw (1).
The oil level should reach the lower edge
of the bore for the screw plug.
- Top up oil through the open bore until
a little oil starts to emerge.
- Reinstall filler and inspection screw
properly.
$
When filling with oil, ensure high standards of cleanliness are observed.
Gear1000.wmf