HPW
HYDRAULIC HIGH PRESSURE WATER PUMPS
OPERATING INSTRUCTIONS
HPW 200/30-45 (-ST)
HPW 420/20-50 (-PA)
HPW 40/40-8
HPW 220/50-70 (-PA)
HPW 520/30-85 (-PA)
HPW 90/150-85 (-PA)
HPW 180/90-115 (-PA)
HPW 460/50-115 (-PA)
HPW 130/180-140 (-PA)
HPW 800/30-140 (-LS)
HPW 1600/15-140
HPW 300/300-350
HPW 1200/100-390
PS
TWP
1
May 2014
HPW - HIGH PRESSURE WATER PUMPS
Question and Answer IconNeed help?

Do you have a question about the Dynaset HPW Series and is the answer not in the manual?

Summary

SAFETY PRECAUTIONS

INSTALLATION

HYDRAULIC SYSTEM INTEGRATION

Connecting the HPW-pump to carrier machine hydraulic systems, including different pump types.

OPERATION

PUMP START-UP AND SHUTDOWN

Procedures for starting, adjusting, and safely stopping the HPW-pump.

ADJUSTING FLOW RATE AND PRESSURE

How to adjust flow rate and pressure based on pump configuration.

BASIC APPLICATIONS

FLUIDS AND MAINTENANCE

ROUTINE MAINTENANCE

Routine maintenance requirements and checks for HPW-pumps.

TROUBLESHOOTING

PUMP NOT WORKING OR NO WATER FLOW

Troubleshooting steps for when the HPW-pump fails to operate or deliver water.

TECHNICAL SPECIFICATIONS

OUTPUT CHARACTERISTICS AND REQUIREMENTS

Detailed technical specifications, including output characteristics and hydraulic requirements.

MANUFACTURERS LIMITED WARRANTY

Summary

SAFETY PRECAUTIONS

INSTALLATION

HYDRAULIC SYSTEM INTEGRATION

Connecting the HPW-pump to carrier machine hydraulic systems, including different pump types.

OPERATION

PUMP START-UP AND SHUTDOWN

Procedures for starting, adjusting, and safely stopping the HPW-pump.

ADJUSTING FLOW RATE AND PRESSURE

How to adjust flow rate and pressure based on pump configuration.

BASIC APPLICATIONS

FLUIDS AND MAINTENANCE

ROUTINE MAINTENANCE

Routine maintenance requirements and checks for HPW-pumps.

TROUBLESHOOTING

PUMP NOT WORKING OR NO WATER FLOW

Troubleshooting steps for when the HPW-pump fails to operate or deliver water.

TECHNICAL SPECIFICATIONS

OUTPUT CHARACTERISTICS AND REQUIREMENTS

Detailed technical specifications, including output characteristics and hydraulic requirements.

MANUFACTURERS LIMITED WARRANTY

Dynaset HPW Series Specifications

General IconGeneral
Flow RateUp to 300 lpm (80 gpm)
WeightVaries by model
Power SourceHydraulic
CategoryWater Pump
Operating TemperatureTypically -20°C to +80°C (-4°F to +176°F), check specific model
Max PressureUp to 350 bar (5000 psi)
PressureUp to 350 bar (5000 psi)