5. ASSEMBLY
5.1. GENERAL
The assembly electrical connection and commissioning must be performed by properly trained,
specialist personnel.
The various connection terminals operate at different voltages, e.g. some are at 24 V
DC
and others
at 230 V
DC/AC
. If the 230V is connected to a 24V input, the SD-BOX will be destroyed.
Protect the box and connection terminals from dust and humidity.
The system is contained inside an electrical box for easy placement. On its lower side, it has some
tabs so it can be easily installed on a 35mm DIN rail. In its final position, the box must be properly
secured.
Before assembly, it must be verified that the box has not been damaged during transport.
The box dimensions are:
Length: 157 mm
Width: 90 mm
Height: 71 mm
5.2. ELECTRICAL CONNECTION
Before the electrical connection, check there is no safety risk for the installer.
Before connecting the batteries, check the voltage at the battery’s terminals is
11-13 V.
Having an UCM control can affect the lift maintenance work.
During lift maintenance procedures, it must be taken into account that the UCM
control is connected. The operator must consider that any action to open the
doors from outside floor level will result in the safety line opening and the
overspeed governor being locked.