Timer: Press to set timer with „up” and „down” buttons,
Can be adjusted 1 to 24 hours.
mode: The sleeping mode operation is effective under Cooling mode is on.
Press button, then the unit will work with low fan speed.
The temperature will auto set up by 1C°after 1 hour and 2C°after 2 hour.
The unit auto stop after 6 hours.
The device will auto shut down if room temperature is over 43C° or below 15C°.
You need to wait 3mins before restart the unit after operation.
If the plug is taken out Timer settings will lost.
Special reminder: there is condensing water recycling hidden within this unit. The
condensing water is partly kept recycling between the condenser and the water
plate. When the water level rises to the upper level, the float switch and water full
indicator (E4) lights on to remind draining water. Please cut off the power supply,
move the appliance to a suitable place, remove the drain plug, drain water
completely. after the drain, re-install the plug, or the appliance may leak and make
your room wet.