Dytran Instruments, Inc. 21592 Marilla St. Chatsworth, CA 91311 Phone: (818) 700-7818 Website: www.dytran.com email: info@dytran.com
Page | 10
Figure 10: Same data set before and after oversampling with 32,000Hz frequency
7.6 “TIME SYNCHRONOUS AVERAGE” button shall perform time domain averaging on the set of data
using a user entered RPM value. The data set will be chopped using frequency from RPM window
and averaged with each other. The user shall be prompted for number of periods to display: