Start-mode Selection
Both the E7 and the E8 are set by default to zero start mode which means the motor will start as soon as you press the gas
accelerator, even when the scooter is stationary.
NON - Non-zero start mode (must be kick-started)
ZERO - zero start mode (motor start even when the scooter is stationary)
Parameter Settings
Long press the MODE and the ON/OFF button at the same time to enter the parameter settings mode. Short press the ON/
OFF button to switch between the different paramteres. Short press the MODE button to change the settings. Long press the
MODE and the ON/OFF button at the same time to save and exit.
P-settings
P0: Wheel diameter; 10"
P01: Cut-off volt; 43-40 volt
P02: Speed calibration; 18
P03: Counter; 1
P04: Speedometer: 0 km/h - 1 mp/h;
P05: zero start(stationary start), non-zero start(kick-start) setting: 0 - zero start; 1 - non-zero start;
P06: Cruise control function: 1 - activated, 0 - deactivated;
P07: Acceleration: 0 = weak, 1 = strong;
P08: Motor effect: 100 is the maximum effect;
P09: Motor brake, 0 = none, 2 = strong;