EasyManua.ls Logo

Eagle Tree Systems eLogger V4 User Manual

Eagle Tree Systems eLogger V4
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Copyright © 2003-2010 Eagle Tree Systems, LLC
Instruction Manual for the eLogger V4
Document Version 1.1, Model # MPRV4-CONN-100, MPRV4-LEADS-100, and MPRV4-LEADS-150
Thank you for your purchase! This instruction manual will guide you through the
installation and operation of your eLogger.
Please read the entire manual carefully before proceeding. If, after you read
the manual (including the Troubleshooting sections!) you have further questions
or problems, please visit our web support page for additional support options, at
http://www.eagletreesystems.com/Support/support.html. Note that the latest
version of this manual is available in PDF form from the Support page of our
website.
Please also fill out the registration form at the end of this manual if you did not
purchase your eLogger directly from Eagle Tree Systems, so we can send you
important update information.
Key Features
Here are a few of the features of the eLogger:
Logs pack current to +/- 100 amps (150 amps with MPRV4-LEADS-150) and voltage from about 5 volts to 80
volts
Current is measured with a true Hall Effects Sensor - NOT a power robbing resistance shunt
Adjustable logging rate (from 50 samples per second to one sample every 5 minutes)
16 times the logging space of the standard eLogger V3, and lossless data compression. Typically logs all
available sensors for about four hours, at 10Hz.
All data are logged to permanent memory, which retains the data even when the power is removed
Fully compatible with our OSD Pro expander
Includes Y cable for throttle position logging
Great for bench monitoring of battery charging also!
Supports the PowerPanel LCD Display
Accepts optional inexpensive sensors for three Temperatures, RPM (brushless, magnetic or optical), Airspeed,
Altitude, GPS, Servo Current, and more
Software computes Wattage, mAH, etc. for complete e-flight data.
Fully Compatible with Windows 7 (32 and 64 bit), Vista, 98SE, ME, Win2K and XP™
Weighs about 0.8 oz (22 grams). Versions with Wire Leads may weigh slightly more.
Comes with our state of the art Windows virtual playback display and graphing software
Powerful Graphing software has advanced charting features, such as amps vs. volts
Internet Updatable firmware - as we add new features or (heaven forbid) have a firmware bug, the update is just a
download away! No need to ship hardware back and forth.
Full support for English and Metric units.
Software has built in English, German and Chinese languages.
Intended Uses
The eLogger was designed for use in Unmanned Radio Controlled models. It is intended to be used exclusively in model planes,
boats and cars. Using the eLogger for other purposes is not supported. Further, using the eLogger in situations where its use or
failure could result in loss of life, bodily injury or property damage is expressly prohibited. Eagle Tree Systems, LLC, is not
responsible for your use of this product, or for any damages or injuries you may cause or sustain as a result of its usage.
Question and Answer IconNeed help?

Do you have a question about the Eagle Tree Systems eLogger V4 and is the answer not in the manual?

Eagle Tree Systems eLogger V4 Specifications

General IconGeneral
Operating Temperature-20°C to 85°C
InterfaceUSB
Sensor InputsTemperature, RPM
Data StorageInternal Flash Memory
Temperature Measurement Range-40°C to 125°C
Supported Sensorsvoltage, current, RPM, temperature, GPS
Data Logging RateUp to 50Hz
Current Measurement RangeWith optional sensors: 0 to 100A or more

Summary

eLogger V4 Key Features

Core Product Features Overview

Details the core functionalities and capabilities of the eLogger V4, covering current, voltage, logging rates, and compatibility.

eLogger V4 Installation and Setup

Connecting to Model's Power System

Explains how to safely connect the eLogger to the model's power system, including crucial voltage warnings.

RPM Sensor Installation Guide

Advanced Sensor Configuration

eLogger Software and PC Connection

Installing the Windows Software

Instructions for installing the eLogger software on a Windows PC, including compatibility information.

Connecting eLogger to PC via USB

Guides on how to connect the eLogger to a PC via USB, detailing connector types and precautions.

eLogger Firmware and Software Setup

Updating eLogger Firmware

Provides steps to update the eLogger's firmware, emphasizing importance and precautions during the process.

Initial eLogger Software Setup

Details the initial setup process of the eLogger with the Windows software, including driver installation.

eLogger Data Logging Settings

eLogger Data Recording and Display

eLogger PC Display Configuration

eLogger Calibration and Operation

Safe eLogger Field Operation

Covers essential operational aspects, including critical safety checks and understanding the eLogger's LED status.

eLogger Data Analysis and Testing

Advanced eLogger Features and Troubleshooting

General Troubleshooting Guide

Offers solutions for common issues encountered with the eLogger, software, and connectivity.

eLogger Troubleshooting Specific Issues

PC Recognition and Connectivity Issues

Provides steps to resolve issues where the PC fails to recognize the connected eLogger.