Description of H3CT-5U V2.0 as an Up Counter with hold mode, its basic operation and relay contact behavior.
Explains that counting continues after power interruption is resumed.
Details that counting restarts from the beginning after power resumption.
Emphasizes personal protective equipment, qualified personnel, and proper usage to prevent injury or equipment damage.
Recommends using a star-type screwdriver and installing a disconnecting device for safety.
Step-by-step guide for setting count and sensitivity values using SELECT and ADVANCE buttons.
Specifies the relay output rating for NO and NC contacts.
Instructions for returning the product to EAPL at the end of its life cycle.
Provides contact information for Electronic Automation Private Limited.
This document describes the H3CT-5U V2.0 Preset Production Counter, an Up Counter with a hold mode designed for industrial applications. It is manufactured by Electronic Automation Private Limited (EAPL).
The H3CT-5U V2.0 operates as an Up Counter. Upon applying rated voltage to the source terminals and connecting a sensor input, the display initializes to "00000" and begins counting input pulses. When the process value reaches a pre-set value, the 1 C/O relay contacts change over (NO) and remain in this state until the power is interrupted or a reset signal is applied.
The device features two operational modes:
Power and Electrical:
Counting and Display:
Environmental and Physical:
Durability:
Installation and Wiring: The device features screw-type terminals for electrical connections. It supports both NPN and PNP proximity sensors, as well as limit switches. Users must select the appropriate sensor type (PNP or NPN/Limit Switch) before powering on the device by shorting terminals 8 and 9 for NPN/Limit Switch or leaving them open for PNP. Limit switches should be connected between terminals 7 and 8.
Programming: The programming sequence involves using "SELECT" and "ADVANCE" buttons on the front panel.
Reset and Hold Functions:
Safety Precautions:
Relay Output: Although the standard relay output rating is 5A, it is recommended to use a rated contactor to switch ON/OFF the load. This practice ensures the longevity and health of the equipment, especially in case of short circuits on the power output lines.
Disposition: Once the product's life cycle is complete, users are encouraged to return the unit to EAPL for proper disposition.
Customer Support: For any inquiries or support, customers can contact Electronic Automation Private Limited at the provided phone numbers or email address.