Instruction Manual
H3CT-5U V2.0
Preset Production Counter
EAPL
Introduction
H3CT- 5U V2.0 is an Up Counter with hold mode.
Apply rated voltage to source terminals and connect the sensor
input, display shows “00000” and starts counting the input pulses.
Once process value reaches set value 1C/O relay contacts
changes over to NO and remain in this state till the power is
interrupted or reset signal is applied.
HOLD MODE: Continues counting after resumption of interrupted
Power.
RESTART MODE: Counting starts from the beginning after the
Resumption of interrupted power.
Box Accessories
One (1) H3CT-5U V2.0
One (1) Instruction Manual
Function Up Counter with hold mode
Rated supply Voltage 85V to 270V AC/DC
Rated frequency 50/60Hz± 5% for AC only
Power consumption
AC Approx. 8VA.
DC Approx. 5W.
Control Output
RLY 1 - 1 C/ O
Rated for 5A @ 250 VAC/ 30VDC(NO)
3A @ 250VAC / 30VDC (NC)
Display 5 digit 7 segment LED,0.30”
Count speed 100Hz max.(min I/P pulse width 5msec)
Range 0 to 99,999 counts
Resetting time 250msec minimum
Recovery Time
2 Sec minimum
Ambient temperature
Operation : -10°C to +55°C
Storage : -25°C to +80°C
Humidity MAX 95% RH @ 40ºC
Service life (under no load)
10
6
operations minimum
Electrical life (under full load)
10
5
operations minimum
Insulation resistance >100M ohm @ 500V DC
Dielectric strength
a) 2.5KV AC, 50Hz for 1 minute.
(Between current carrying& non-
current carrying parts)
b) 1.5KV AC, 50Hz for 1 minute.
(Between contacts & control circuit)
c) 750V AC, 50Hz for 1 minute.
(Between non-continuous relay
contacts)
Electrical connection
Screw type terminals with self lifting
clamps
Dimension 48 x 48 x 95.5mm (W x H x D)
Sensor type Proximity NPN / PNP and Limit Switch.
Technical Specification:
Safety Precautions
Read and follow all the safety precautions and instructions
before installing and working with the equipment.
!
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC
FLASH
Apply appropriate personal protective equipment(PPE) and
follow safety work practices
Only qualified electrical workers should install this equipment.
Such work should be performed only after reading this entire
set of instructions.
If the equipment is not used in the manner specified by the
manufacturer, the protection provided by the equipment
may be impaired.
NEVER work alone.
The successful operation of this equipment depends upon
proper handling, installation and operation. Neglecting
fundamental installation requirements may lead to personal
injury as well as damage to electrical equipment or other
property.
NEVER bypass external fusing.
Failure to follow these instructions will result in death or serious
injury.
EAPL is not responsible for any consequential damages arising
out of use of our products, though the technology is cautiously
chosen and implemented like any other well designed good
electric device.
Tools and Fasteners
Kindly use star – type screw driver for tightening the screws.
NOTE: Installation should include a disconnecting device, like
switch or circuit breaker, with clear ON/OFF markings, to turn-
off the auxiliary supply (control power).The disconnecting
device should be within the reach of the equipment and the
operator.
OD RH YN 610002 REV 02/23-08-2021 Page 1 of 2
Question and Answer IconNeed help?

Do you have a question about the EAPL H3CT-5U V2.0 and is the answer not in the manual?

Summary

Product Introduction and Operation Modes

Product Introduction

Description of H3CT-5U V2.0 as an Up Counter with hold mode, its basic operation and relay contact behavior.

Hold Mode

Explains that counting continues after power interruption is resumed.

Restart Mode

Details that counting restarts from the beginning after power resumption.

Technical Specifications

Safety Precautions and Installation Guidance

General Safety Warnings

Emphasizes personal protective equipment, qualified personnel, and proper usage to prevent injury or equipment damage.

Tools and Fasteners

Recommends using a star-type screwdriver and installing a disconnecting device for safety.

Product Dimensions

Front Panel and Rear View

Terminal Details and Wiring

Programming Instructions

Programming Example

Step-by-step guide for setting count and sensitivity values using SELECT and ADVANCE buttons.

Contact Information and Product Disposition

Contact Rating

Specifies the relay output rating for NO and NC contacts.

Product Disposition

Instructions for returning the product to EAPL at the end of its life cycle.

Contact Details

Provides contact information for Electronic Automation Private Limited.

Overview

This document describes the H3CT-5U V2.0 Preset Production Counter, an Up Counter with a hold mode designed for industrial applications. It is manufactured by Electronic Automation Private Limited (EAPL).

Function Description

The H3CT-5U V2.0 operates as an Up Counter. Upon applying rated voltage to the source terminals and connecting a sensor input, the display initializes to "00000" and begins counting input pulses. When the process value reaches a pre-set value, the 1 C/O relay contacts change over (NO) and remain in this state until the power is interrupted or a reset signal is applied.

The device features two operational modes:

  • HOLD MODE: In this mode, counting continues from the last recorded count after the resumption of interrupted power.
  • RESTART MODE: In this mode, counting restarts from the beginning (00000) after the resumption of interrupted power.

Important Technical Specifications

Power and Electrical:

  • Rated Supply Voltage: 85V to 270V AC/DC.
  • Rated Frequency: 50/60Hz ± 5% for AC only.
  • Power Consumption: Approximately 8VA (AC) and 5W (DC).
  • Control Output: RLY 1 - 1 C/O.
    • Rated for 5A @ 250 VAC / 30VDC (NO).
    • Rated for 3A @ 250VAC / 30VDC (NC).
  • Insulation Resistance: >100M ohm @ 500V DC.
  • Dielectric Strength:
    • 2.5KV AC, 50Hz for 1 minute (between current carrying & non-current carrying parts).
    • 1.5KV AC, 50Hz for 1 minute (between contacts & control circuit).
    • 750V AC, 50Hz for 1 minute (between non-continuous relay contacts).
  • Electrical Connection: Screw type terminals with self-lifting clamps.

Counting and Display:

  • Display: 5-digit 7-segment LED, 0.30" height.
  • Count Speed: 100Hz maximum (minimum input pulse width 5msec).
  • Range: 0 to 99,999 counts.
  • Resetting Time: 250msec minimum.
  • Recovery Time: 2 seconds minimum.

Environmental and Physical:

  • Ambient Temperature:
    • Operation: -10°C to +55°C.
    • Storage: -25°C to +80°C.
  • Humidity: Maximum 95% RH @ 40°C.
  • Dimensions: 48 x 48 x 95.5mm (W x H x D).
  • Sensor Type: Compatible with Proximity NPN / PNP and Limit Switch.

Durability:

  • Service Life (under no load): 10^6 operations minimum.
  • Electrical Life (under full load): 10^5 operations minimum.

Usage Features

Installation and Wiring: The device features screw-type terminals for electrical connections. It supports both NPN and PNP proximity sensors, as well as limit switches. Users must select the appropriate sensor type (PNP or NPN/Limit Switch) before powering on the device by shorting terminals 8 and 9 for NPN/Limit Switch or leaving them open for PNP. Limit switches should be connected between terminals 7 and 8.

Programming: The programming sequence involves using "SELECT" and "ADVANCE" buttons on the front panel.

  1. Setting the Count Value: Press "SELECT" once to enter set mode. The display will show "SET" for 2 seconds, then the previous set value with the Most Significant Digit (MSD) flashing. Use "ADVANCE" to change the flashing digit. Press "SELECT" again to move to the next digit. Repeat this process for all 5 digits.
  2. Saving the Count Value: After setting the last digit, press "SELECT" again. The set value is saved, and the display shows "SEnS" for 2 seconds, followed by the previous sensitivity value.
  3. Setting Sensitivity: Use "ADVANCE" to adjust the sensitivity value (e.g., to 100).
  4. Exiting Programming: Press "SELECT" again. The display will show "00000", indicating the counter is ready for operation.

Reset and Hold Functions:

  • RESET: Shorting terminals 12 and 10 for at least 250ms will reset the counter.
  • HOLD: Shorting terminals 11 and 10 will activate the hold function. Opening these terminals will revert to RESTART mode.

Safety Precautions:

  • DANGER: HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH.
  • Always use appropriate Personal Protective Equipment (PPE) and follow safety work practices.
  • Only qualified electrical workers should install this equipment after reading the entire set of instructions.
  • If the equipment is not used as specified by the manufacturer, its protection may be impaired.
  • Never work alone.
  • Proper handling, installation, and operation are crucial for successful operation.
  • Never bypass external fusing.
  • Installation must include a disconnecting device (switch or circuit breaker) with clear ON/OFF markings, accessible to the operator, to turn off the auxiliary supply.
  • EAPL is not responsible for consequential damages arising from product use.

Maintenance Features

Relay Output: Although the standard relay output rating is 5A, it is recommended to use a rated contactor to switch ON/OFF the load. This practice ensures the longevity and health of the equipment, especially in case of short circuits on the power output lines.

Disposition: Once the product's life cycle is complete, users are encouraged to return the unit to EAPL for proper disposition.

Customer Support: For any inquiries or support, customers can contact Electronic Automation Private Limited at the provided phone numbers or email address.