Installation & Operations
050-080-001 Rev 6

Questions and Answers

  • J
    jeanette04Aug 10, 2025
    Why air hammering following EasyWater IRON SHIELD GX7 Water Filtration Systems regeneration?
    • W
      walkerhannahAug 10, 2025
      If you notice air hammering following system regeneration in your EasyWater Water Filtration System, it's likely due to an inadequate flow rate required for filter backwash. Refer to Section ‘3.1 Filtration Specs’ for the Minimum Backwash Flow Rate requirements listed for your model. Ensure that the minimum Backwash Flow Rate is maintained throughout the entire regeneration cycle.
  • R
    Robin DunnAug 15, 2025
    Why EasyWater IRON SHIELD GX7 water is cloudy?
    • P
      Paul MossAug 16, 2025
      If your EasyWater Water Filtration System results in cloudy water that clears after a few seconds, it's likely due to higher levels of dissolved oxygen naturally present in unfiltered water. To address this, lower the ‘Air Charge Time’ from 40 minutes to 30 minutes. Note: If iron or H2S return after lowering the ‘Air Charge Time’ reset the ‘Air Charge Time’ to original manufacturer setting.
  • A
    Aaron JonesAug 21, 2025
    What to do if iron or odor returns after months of operation of EasyWater IRON SHIELD GX7?
    • C
      colemanalyssaAug 21, 2025
      If iron or odor returns after months of operation of your EasyWater Water Filtration System, it is likely due to a clogged injector. Perform the recommended maintenance as described in Section ‘9. Maintenance’.
  • G
    Glenn JohnsonAug 26, 2025
    Why H2S/rotten egg odor remains/returns in EasyWater IRON SHIELD GX7?
    • M
      maciasjeffreyAug 27, 2025
      If you continue to experience H2S or a rotten egg odor with your EasyWater Water Filtration System, it's likely due to a regeneration frequency that is too low. Increase the regeneration frequency (Day Override).
  • S
    Samuel WatsonAug 31, 2025
    How to remove media fines from EasyWater Water Filtration Systems?
    • A
      Amber HurstAug 31, 2025
      If you find media fines coming through your EasyWater Water Filtration System and clogging faucet aerators, shower heads, or tubs, it's likely due to inadequate media soak/startup. To flush the media out of the plumbing lines: 1. Shut off the home’s main cold water line. 2. Remove aerators or shower heads from faucets and showers where media has clogged. 3. With the main cold water line off and aerators/shower heads removed, turn the cold water on full stream at each faucet/tub/shower location. 4. Leave the cold water running at each location. 5. Turn the home’s main cold water line back on to clear air from the lines. 6. Repeat the above steps until all locations run clear. 7. Reinstall the faucet aerators and shower heads once the water runs clear.
  • G
    Greg CalhounNov 5, 2025
    What to do if EasyWater IRON SHIELD GX7 Water Filtration Systems unable to recognize start of regeneration?
    • P
      pharrisonNov 5, 2025
      If the EasyWater Water Filtration System doesn't recognize the start of regeneration, it might be due to several reasons. It could be that the control valve has just been serviced or the control valve piston is not in the home position; in both cases, press and hold the ‘NEXT’ and ‘REGEN’ buttons for 3-5 seconds. Another cause may be a motor issue: check the motor and wiring, and replace the motor if necessary. The drive gear label might be dirty or damaged, or the gear could be missing or broken, so replace or clean the drive gear. Also, the drive bracket may be incorrectly aligned to the back plate, so reseat the drive bracket properly. Finally, the PC board could be damaged, defective or incorrectly aligned to the drive bracket, so replace the PC board or ensure it is correctly snapped ...

Summary

Unpacking and Inspection

How It Works

Specifications

Filtration Specifications

Details filtration parameters like flow rates, pressure, and contaminant limits for different models.

System Dimensions

Provides physical dimensions for the water treatment system's tanks.

Control Valve Electrical Specifications

Outlines the electrical requirements for the control valve.

Installation

Pre-Installation Procedures

Steps and considerations before beginning the physical installation process.

Installation Preparation

Initial steps to prepare for installation, including shutting off water and lubricating parts.

Control Valve Installation on Tank

Detailed instructions for attaching the control valve to the media tank.

Plumbing Connections

Guides on connecting the system to the home's water supply and drain.

Drain Line Installation and Options

Instructions for plumbing the drain line and specifying minimum drain line sizes.

System Startup

Bypass Configuration

Sequence of Installation

System Programming

Regeneration Time and Frequency Programming

Instructions for setting the regeneration schedule and frequency parameters.

GX7 Model Programming Settings

Configuration details for specific GX7 model series settings.

Maintenance

Recommended Maintenance Schedule

Provides a schedule for recommended maintenance tasks based on water quality.

Injector and Internal Screen Cleaning

Step-by-step guide on how to clean the system's injector and internal screen.

Peroxide Wash Procedure

Procedure for performing a peroxide wash for system cleaning.

Service Wrench and Component View

Details on an optional service tool and a component breakdown of the control valve.

Stack Assembly and Piston Service

Instructions for servicing the stack assembly and piston components.

Troubleshooting

Limited Warranty

EasyWater IRON SHIELD GX7 Specifications

General IconGeneral
BrandEasyWater
ModelIRON SHIELD GX7
CategoryWater Filtration Systems
LanguageEnglish