Output Shaft Speed Sensor | Removal and Installation TRSM0940
Output Shaft Speed Sensor Installation
Important: Lubricate sensor with Eaton lubricant 5564527.
1. Using a smooth, twisting motion, fully insert the Out-
put Shaft Speed Sensor in the Transmission Rear Bear-
ing Cover opening.
2. Install the Retaining Bolt and tighten to 8–10 lb-ft
(11–13 N•m).
3. Apply included material to the Sensor Connector termi-
nals.
Note: Apply just enough material to cover the end of
the terminal.
Note: Use only Eaton lubricant 5564527. (Nye Lubri-
cants NYOGEL 760G - For MSDS safety or other infor-
mation see www.nyelubricants.com)
4. Reconnect the Transmission Harness to the Output
Shaft Speed Sensor and install the cable tie.
!