TRSM0940 Removal and Installation | Range Valve
Range Valve Installation
Important: Lubricate O-rings with Eaton Fuller silicone
71214 or equivalent.
Important: The valve is keyed to fit its mounting location.
Take care to align the key with the notch in the housing.
1. Install and push the Range Valve down into the hous-
ing.
2. Using a 5/16” socket, install the 4 Range Valve mount-
ing cap screws and tighten to 21–27 lb-in (2.3–3.0
N•m) using a cross pattern.
3. Reconnect the Transmission Harness to the Range
Valve and close all air tanks drains.
Note: Install the Range Harness back into the cable tie
on the Range Valve.
4. If equipped, install the Protective Cover. Push the cover
down by hand until it snaps into place.
!
!