2022.10.7
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
143
TRSM0940 Removal and Installation | Input Shaft Speed Sensor 
Input Shaft Speed Sensor Installation
Important: Clean the mounting surface on the housing and 
remove any burrs or sharp edges.
Important: Lubricate the O-ring with Eaton Fuller silicone 
71214 or equivalent.
1. Using a smooth, twisting motion, fully insert the Input 
Shaft Speed Sensor in the Transmission Shift Bar 
Housing opening.
2. Using a 3/8” socket, install the retaining bolt and 
tighten to 8–10 lb-ft (11–13 N•m).
3. Reconnect the Transmission Harness to the Input Shaft 
Speed Sensor or pigtail connector, if equipped.