90
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
2022.10.7
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation | Auxiliary Section Service Procedures TRSM0940
Auxiliary Section Installation
1. Attach the Auxiliary Section lifting bracket to the top of 
the Auxiliary Case.
2. Position a new Auxiliary Case Gasket on the mounting 
surface of the Main Case.
3. Install the Auxiliary Case Assembly onto the transmis-
sion Main Case dowel pins. Using the Output Shaft, 
wiggle the auxiliary case forward until it is as far for-
ward as possible. Remove the auxiliary section lifting 
bracket.