EasyManua.ls Logo

Eaton RTLO-16918B - PTO Operation; UltraShift and AutoShift PTO Operation

Eaton RTLO-16918B
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PTO with Confirm Switched to Power
From To Description Notes
TCM - B-14 DPST - SW01 PTO Request
DPST - SW02 TCM - B-15 PTO Request
TCM - B-5 PTO Engage Relay -
86
PTO Engage
PTO Engage Relay -
85
TCM - B-2 PTO Engage
Vbatt DPST - SW03 PTO Power Vbatt should be fused to protect wiring
to
PTO and PTO.
DPST - SW04 PTO Engage Relay -
30
PTO Engage
PTO Engage Relay -
87
PTO - PTO-Power PTO Engage
PTO - PTO-Ground Chassis GND PTO Ground
PTO - PTO-Confirm
PTO Confirm Relay - 85 PTO Confirm Splice
PTO Lamp/LED - L(+)
PTO Lamp/LED - L(-) Chassis GND PTO Confirm
PTO Confirm Relay -
86
Chassis GND PTO Confirm Splice
PTO Confirm Relay -
30
PTO Confirm Relay -
87
TCM - B-16
PTO Confirm
Connector B (TCM mating end)
20
10
19
9
18
8
17
7
16
6
15
5
14
4
13
3
12
2
11
1
16 15 14
25
47
PTO Interface

Table of Contents