Transmission appearance may differ, procedure is the same.
19
External Parts
Lube System
How to Install the Oil Tube and Oil Pan/Strainer
Special Instructions
If the magnet needs to be replaced, use adhesive
#71210 or equivalent and cover the entire mating
surface.
Special Tools
Typical service mechanic tools
To Install
1. If previously removed, install the strainer
capscrews. Tighten to 5-7 Lb
f
·ft of torque.
2. Position a new oil pan gasket and the oil transfer
tube.
3. Install the two (2) retaining capscrews. Tighten
the screws to 14-20 Lb
f
·ft of torque.
4. Position the oil pan.
5. Install the retaining capscrews. Tighten the
screws to 14-20 Lb
f
·ft of torque.
6. If previously removed, install the dip stick adaptor
O-ring and fitting. Tighten to 34-48 Lb
f
·ft of
torque.
7. If previously removed, install the oil return
adaptor O-ring and adaptor. Tighten to 34-48
Lb
f
·ft of torque.
8. If previously removed, install a new return tube
fitting on the transmission. Tighten to 60-75
Lb
f
·ft of torque.
9. Install the return tube on the sump pan. Tighten
to 60-75 Lb
f
·ft of torque.
Final Check
Make sure all connector are properly torqued.
H/50-2
H/50-1
H/49-9
H/49-8
4
2
3
5
6
8, 9
7
1