FOLLOW PROPER LOCKOUT PROCEDURE BEFORE SERVICING THIS EQUIPMENT.
DANGER
DANGER
GARNET REMOVAL INSTALLATION REGISTRATION AND ACCEPTANCE FORM
1. System is positioned properly.
2.
Sweeper package has been installed according to drawing provided
by Ebbco.
3. All external connections have been made between Garnet Removal System and waterjet catch tank; and
proper air supply has been hooked up to plant air minimum 80 PSI @ 2 SCFM.
4. System runs with a 4 to 10 PSI pressure differential between inlet and outlet of separator.*
5.
Good water movement in waterjet catcher tank
.
6. System runs with no leaks.
7. Purge is set for a four (4) second purge every 60 seconds; water should flow back from the Garnet Hopper to
the waterjet cutting tank.*
8.
Customer understands how system works and how to service the strainer ba
sket.
9.
Customer knows how, and when, to empty spent Garnet Hopper.*
10. Overflow baffle is installed in Garnet Hopper.*
11. Use only Ebbco certified consumables and replacement parts. Failure to do so may cause catastrophic
failure.
12. System is designed to run simultaneously with waterjet. Always run your Garnet Removal System while you
cu
t.
*Note: Item numbers 4, 7, 9, and 10 must be followed and maintained or warranty is null and void.
Failure to follow above instructions can lead to catastrophic failure of the Ebbco Garnet Removal System as well as poor
performance. The Garnet Removal System has been installed and is operating correctly according to the service manual.
I have read and understand the Ebbco Service Manual. I agree that proper system maintenance and filter change out will
be adhered to.
OPERATING PRESSURES
Inlet Outlet Vac
Ebbco Technician (if on site) Company
Supervisor Contact Name
Operator Contact Phone Number
Operator Contact E-Mail Address
INSTALL DATE: SERIAL NO:
NOTE: Warranty on equipment is null and void if this form is not completed and returned
to Ebbco upon installation. Email to: customerservice@ahbinc.com
6/3/08