21
www.eberg.eu
HUMIEN
9. CLEANING AND MAINTENANCE
10. STORAGE
The device is equipped with a water softening lter. It is mounted to the lid of the water tank.
• The lter is removed from the lid for replacement with a new one by turning clockwise. After turning,
the lter will be unlocked and disconnect from the age.
• The new lter is installed by sliding the lter into a round socket in the tank lid and turning the lter
counterclockwise. After proper installation, the lter should be blocked in the lid of the water tank. The
lter should not move.
If the device will not be used for an extended period of time, please ensure that it is properly stored.
• Empty the water tank and make sure that there is no water left in the tank and inside the machine.
• Leave the tank and the device to dry naturally and completely before storage.
• Place the device in the original box and store in a cool, dry place.
ATTENTION: The humidier may clog or not work properly if stored without being completely dry. Make
sure the humidier is completely dry before storage.
Because of the risk of electric shock, always disconnect the power
supply and pull out the plug before cleaning work.
• Unscrew the tank cap, pour out the water, wipe the sediment with
a soft cloth and rinse it with clean water.
• Clean the tray once a week. Wipe o the residue with a soft cloth
moistened with a cleaning agent, then wash it with water.
• The humidier housing should be cleaned with a soft cloth rinsed
in warm water and then wiped dry.
• Cleaning the spray nozzle. If there is sediment on the surface,
clean it with a cotton swab, and then wash it with clean water.
• Cleaning the PTC heating element (preferably once a week). If
there is sediment and dirt on the surface of the PTC heater, wipe
o the tarnish with a cotton swab or soft cloth, and then wash it
with clean water.
8. INSTALLATION OF THE DESCALING FILTER