EasyManua.ls Logo

Ecler WPTOUCH - CONFIGURATION Mode

Ecler WPTOUCH
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
4.2.2. CONFIGURATION Mode
This mode allows you to modify the WPTOUCH following
parameters:
For both modes, analogue and digital
1. "EDIT SOURCE NAME", "EDIT DEVICE NAME".
Type of information displayed on line 1 of the LCD
display: selection of active source or device name.
2. "LCD CONTRAST". From 0 to 60.
For analogue mode only:
1. "DC CONTROL". Type of analogue volume control:
linear (LIN) or antilog (ANTILOG). Défault: LIN.
Defines the curve shape of the 0-10V DC voltage
volume control related to the WPTOUCH volume
control (wheel).
2. "REMOTE TYPE". Enables the remote control
functions: volume and source selection (VOL +
SELECT) or only volume (VOL). Please remember
that the WPTOUCH is able to affect the volume
remote control port (0 - 10V DC) of processors
(AMIC, AMIC24), amplifiers (AMPACK 25, 80, 2-70
and 4-70, MPA series, NZA series, etc.). In these
cases, the ideal setting is VOL.
3. "SOURCES". Max number of possible source
selections: between 1 and 17. Default: 5. One
source always corresponds to "OFF", i.e. no source
selected. So, the number of sources must be set
between 1 and n +1, where n is the number of
available sources. For proper operation this
parameter should never be set to a value greater
than n +1.
4. "VOLUME MIN". Minimum volume level: between 0
and the maximum level. Default: 0
5. "VOLUME MAX". Maximum volume level: between
the minimum and 100. Default: 100
6. "BACKLIGHT". LCD display illumination: ON / OFF.
Default: ON. When ON, using the touch controls
automatically activates LCD backlighting. It turns off
a few seconds after the last action.
7. "FACTORY DEF". Restore all WPTOUCH default
parameters.
To access the CONFIGURATION Mode, the sequence to
follow is: