1


1. Before starting: Naming of each part

 


Main power LED
Operation LED
Reset button

USB / RS232 Select S/W.
RS232 Port
USB Port
Sample connect
Power S/W.
Fuse
Power cord
Earth
HALL EFFECT MEASUREMENT SYSTEM
HMS-3000
 
 
2
 
Liquid Nitrogen Inlet
Sample Board Connector
Main Body Connector
Sample Board
MagnetSet Case
Permanent Magnet
N
N
Question and Answer IconNeed help?

Do you have a question about the Ecopia HMS-300 and is the answer not in the manual?

Ecopia HMS-300 Specifications

General IconGeneral
BrandEcopia
ModelHMS-300
CategoryMeasuring Instruments
LanguageEnglish

Summary

1. Getting Started: Part Identification

Main Body - Front Panel Components

Identifies front panel components of the Hall Effect Measurement System.

Main Body - Rear Panel Components

Identifies back panel components of the Hall Effect Measurement System.

Magnet Set Components

Illustrates and names components of the magnet set.

2. Initial Setup and Connections

Connect Main Body to AC Power

Details connecting the AC power cable to the main unit.

Connect Main Body to PC via RS232

Explains connecting the main unit to a PC via RS232.

Connect Main Body to PC via USB

Explains connecting the main unit to a PC via USB.

Connect Sample to Magnet Set

Details connecting the sample cable to the main body and magnet set.

3. Software Installation and Setup

Install Measurement Software from CD-ROM

Guides installation of the measurement software from CD-ROM.

Prepare for 77K Measurement

Notes the requirement for liquid nitrogen for 77K measurements.

RS232C Cable Connection Setup

Details RS232C connection setup and port confirmation.

HMS3000 Software Installation Process

Software File Extraction

Shows the software installation file extraction progress.

Installation Completion and Reboot

Indicates successful software installation and prompts for reboot.

Hall Effect Measurement System Main Interface

Displays the main interface of the Hall Effect Measurement System software.

USB Connection and Driver Setup

Set Main Body Switch to USB

Instructs to set the rear switch to USB for connection.

Connect USB Cable and Start Wizard

Guides connecting the USB cable and initiating the hardware setup wizard.

Configure USB Driver Search Options

Configures search options for installing the USB driver.

USB Driver Search Progress

Shows the wizard searching for the USB driver.

USB Serial Port Driver Installation

USB Driver Installation Progress

Shows the wizard installing the USB driver software.

USB Driver Installation Complete

Confirms the completion of the USB driver installation.

Welcome to USB Serial Port Wizard

Welcomes the user to the USB Serial Port installation wizard.

Select USB Serial Port Driver Search Location

Guides selection of driver search locations for the USB Serial Port.

Verifying USB Serial Port Configuration

Searching for USB Serial Port Driver

Shows the wizard searching for the USB Serial Port driver.

Installing USB Serial Port Driver Files

Shows the wizard installing the USB Serial Port driver files.

Completing USB Serial Port Driver Setup

Confirms the completion of the USB Serial Port driver installation.

Verify USB Serial Port Setup via System Properties

Guides checking the installed USB Serial Port via My Computer properties.

Device Manager and Port Settings

Accessing System Device Manager

Accessing Device Manager through System Properties.

Locating COM Ports in Device Manager

Navigating to Ports (COM & LPT) in Device Manager.

View USB Serial Port Properties

Displays properties of the installed USB Serial Port.

Advanced COM Port Configuration

Configure USB Serial Port General Settings

Shows general and port settings for the USB Serial Port.

Advanced COM Port Configuration Options

Configures advanced settings like FIFO buffers for the COM port.

Select Correct COM Port Number

Guides selection of the correct COM port number for the device.

USB Driver File Management

Shows files related to USB driver deletion.

USB Driver Removal Process

Initiate USB Driver Uninstallation

Initiates the USB driver uninstallation process.

Complete USB Driver Uninstallation

Confirms the completion of the USB driver uninstallation.

4. Using the Measurement Software

Hall Effect Measurement Program: Initial Screen

Shows the initial screen of the Hall Effect Measurement System software.

Software Navigation: START and EXIT

Explains the function of the 'START MEASUREMENT' and 'EXIT' buttons.

Software Data Input and Output

Input Parameters for Measurement

Details input fields for measurement parameters like date, user, sample name, etc.

Viewing Collected Measurement Data

Displays the raw measurement data collected by the system.

Understanding Measurement Results

Shows the calculated results derived from the measurement data.

Software Control Buttons Overview

HELP Button Function

Explains the function of the HELP button.

Go To I-V Curve Function

Describes navigating to the I-V Curve window.

Communication Test Function

Explains the Comm. Test function for checking system connection.

Start Measurement Function

Describes starting measurement after inputting values.

Save Measurement Data Function

Explains saving measured data and results.

Recalculate Results Function

Describes recalculating results based on changed data.

Stop/Continue Measurement Function

Explains toggling between measuring and stopping.

Clear Data Function

Describes clearing measurement data and results.

Print Screen Function

Explains printing screen contents.

Close Program Function

Describes exiting the program.

4-2. I-V Property Measurement Program

I-V Measurement Input Parameters

Details input fields for I-V measurement parameters like current, temperature, etc.

I-V Measurement Program Screen Layout

Shows the overall composition of the I-V measurement software screen.

Curve Visualization and Data Display

I-V Curve Visualization

Shows hall voltage change versus applied current as a graph.

I-R Curve Visualization

Shows sheet resistance change as applied current as a graph.

I-V Data View

Displays the raw data results from the I-V curve measurement.

Data Management and Program Control

Save Measurement Data

Save measured data and results value.

Load Saved Graph Data

Recursion existingly saved graph data.

Redraw Graph Function

Get the graph into line and regraph it again.

Stop/Resume Measurement

Toggle between STOP operating when measuring, and CONTINUE measuring when stopped.

Clear Measurement Data

Clear measurement data and results value.

Print Current Screen

Print the screen contents.

Exit Program

Program ending.

Access Help Information

Open the "Help" window.

5. Measurement Procedure Overview

5-1. Sample Arrangement and Bonding

Details the procedure for preparing and bonding the sample for measurement.

Recommended Sample Bonding Techniques

Illustrates acceptable and not recommended methods for sample bonding.

Inserting Sample Board into Magnet Set

Guides inserting the Sample Board into the magnet set.

5-2. System Power On Procedure

5-3. Liquid Nitrogen for 77K Measurement

5-4. Operating the Measurement Software

Launching the PC Measurement Program

Initial step to launch the measurement software.

Performing Communication Test

Verifies system connection and communication readiness.

Setting Input Parameters for Measurement

Entering current range, input values, magnetic flux density, and sample thickness.

Initiating the Measurement Process

Describes using the 'Measure' button and expected outputs.

Magnet Insertion and Data Acquisition

Guides magnet insertion and subsequent measurements.

6. Usage Precautions and Safety

Electrical and Magnet Handling Safety

Advises on using standard AC outlets and handling the magnet safely.

Sample Handling and Environmental Care

Emphasizes keeping the sample clean and following safety procedures.

Repair and Environmental Condition Warnings

Warns against adverse environmental conditions and unauthorized repairs.

Fuse Replacement Guidelines

Details fuse replacement procedures and specifications.

7. Product Specifications and Contents

Technical Product Specifications

Lists the technical specifications of the Hall Effect Measurement System.

Software Environment and Measurement Types

Details software requirements and measured parameters.

Included Product Components

Lists all components included with the Hall Effect Measurement System.

Warranty Information

Consumer Damage Compensation Policy

Outlines compensation policies for various types of product damage.

Manufacturer Contact Details