ECTIVE BB & SBB 27
Recommended Cable Cross-Sections, Cable
Lengths and Fuse Capacities
BB25, BB30
2.5mm
2
4mm
2
6mm
2
10mm
2
Cable length “+Start II” - - up to 5m up to 8m
Cable length with insulated
construction “-Batt”
- - up to 5m up to 8m
“Fuse II” cable protection - - 50A 50A
Cable length “-Com” to
“Board I”
- 0.5 to 1.5m 1.0 to 2.5m 2.0 to 4.0m
Cable length “+ Board I” - 0.5 to 1.5m 1.0 to 2.5m 2.0 to 4.0m
“Fuse I” cable protection - 40A 40A 40A
BB50, BB60
4mm
2
6mm
2
10mm
2
16mm
2
25mm
2
Cable length
“+Start II”
- - - up to 7m up to 10m
Cable length
with insulated
construction “-Batt”
- - - up to 7m up to 10m
“Fuse II” cable
protection
- - - 100A 100A
Cable length
“-Com” to “Board I”
- - 0.5 to 2.0m 1.5 to 3.0m 2.5 to 5.0m
Cable length
“+ Board I”
- - 0.5 to 2.0m 1.5 to 3.0m 2.5 to 5.0m
“Fuse I” cable
protection
- - 80A 80A 80A