USER’S GUIDE
HAZ-DUST HD-7204
REAL-TIME PERSONAL DUST
MONITOR
MODEL HD-7204
DOC# HD7024 0719
Environmental Devices Corporation
Fieldstone Industrial Park
4 Wilder Drive Bldg. # 15
Plaistow, NH 03865
USA
Phone: (603) 378-2112
(800) 234-2589
Fax: (603) 378-2113
E-mail: sales@hazdust.com
E-mail: customerservice@hazdust.com
E-mail: techsupport@hazdust.com
Website: www.hazdust.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the edc HAZ-DUST HD-7204 and is the answer not in the manual?

edc HAZ-DUST HD-7204 Specifications

General IconGeneral
Resolution0.001 mg/m³
Battery Life8 hours continuous use
DisplayLCD
Particle Size Range0.1 to 10 µm
Data LoggingYes
Operating Temperature-10 to 50°C
Storage Temperature-20 to 60°C
Power SupplyRechargeable battery or AC adapter
Operating Humidity0 to 95% RH non-condensing

Summary

Section One: Introduction to the HD-7204

Specifications of the HD-7204

Provides detailed specifications for the HD-7204, including calibration, accuracy, range, and physical dimensions.

Section Two: Operating Parameters of the HD-7204

Cross Calibration

Explains the process of cross-calibration to compensate for variances between test dust and site aerosols.

Setting the Alarm

Details how to set audible ceiling and STEL alarms to alert users of threshold limits.

Section Three: Operating the HD-7204

Selecting the Particle Size

Details the different particulate types (Thoracic, Respirable, Inhalable) and their corresponding required inlets.

Auto-Zero

Explains the zero calibration process, including inserting the zeroing filter and the auto-zero function.

Sampling Procedure

Outlines the necessary conditions and steps to begin a sampling run with the HD-7204.

Infield Calibration Verification

Explains how to verify the instrument's calibration using the Calibration Span Reference accessory.

Faults

Describes common faults such as flow faults and battery faults, and their indicators.

Uploading Data

Provides steps for connecting the HD-7204 to a PC and uploading data using HAZCOMM Pro Software.

Section Four: DustComm Pro Software

Installing DustComm Pro Software

Provides step-by-step instructions for installing the DustComm Pro software on a Windows 10 computer.

Downloading Data

Covers the three major steps for downloading data from the EDC unit to a PC using DustComm Pro.

Section Five: Maintenance of the HD-7204

Checking the Calibration Span

Explains how to verify the instrument's calibration status and the conditions for checking it.

Battery Maintenance

Covers important notes and cautions regarding battery use, maintenance, and warranty.

Charging the Battery

Provides guidelines and conditions for charging the HD-7204 battery using the approved charger.

Cleaning the Sensor Optics

Details the procedure for cleaning the optical sensor to ensure accurate instrument readings.