INTUBATED SYSTEM
INTUBATED SYSTEM:
Further to the general prescriptions for the fumes duct
and flue, the intubated system:
must operate in negative pressure;
must be open to inspection
must observe local regulations.
THE CHIMNEY POT
THE CHIMNEY POT
must be windproof
must have an internal cross section equivalent to
that of the flue and a fumes outlet at least double
that of the interior of the flue
for dual flues (which should be spaced at least 2
m apart) the chimney pot receiving the fumes from
the solid fuel appliance or that from the higher
storey, must be at least 50 cm higher than the other
it must extend beyond the back flow zone (in Italy,
refer to UNI 10683 point 6.5.8.)
it must allow for maintenance of the chimney
INSTALLATION