INSTRUCTION AND
SECURITY MANUAL
MAJ - 06/16
CABLE REPLACEMENT
a
b
1
1
3
5
3
2
2
4
4
5
Unscrew the axis that maintain the pulley and
remove it, using a 17 mm (11/16”) at wrench and
an 8 mm (5/16”) hex wrench.
Put the axis through the cable loop to x it on the
main pipe.
Remove the pulley.
Unscrew the screw from the
main body with a 5 mm (3/16”)
hex wrench, in order to
remove the cable completely.
Put the pulley back to its location.
Pull the mast pipe to remove it completely.
Fix the opposite cable loop on the main body with
the provided screw.
Unscrew
the nut from
the axis that
maintain the
cable at the
mast pipe. Use
a 10 mm (3/8”)
at wrench and
a 5 mm (3/16”)
hex wrench.
Put the principal pipe back in the main
body.
Put the axis maintaining the pulley back
and tighten the nut on the axis with a
17 mm (11/16”) at wrench and an 8 mm
(5/16”) hex wrench.
For this step, the main pipe must not be
completely inserted in the main body.
NECESSARY TOOLS : 10 (3/8”) and 17 mm (11/16”) flat wrench, 5 (3/16”) and 8 mm (5/16”) hex wrench
WITHDRAWAL OF USED CABLE
NEW CABLE INSTALLATION
Ref. 267355