P/N 46000-1320, Rev. 1.6
Installation Instructions &
Owner’s Operation Manual
for Two to Eight Zone
2400 Series
Fire Alarm Control Panels

Table of Contents

Questions and Answers:

Edwards Signaling 2412 Specifications

General IconGeneral
BrandEdwards Signaling
Model2412
CategoryControl Panel
LanguageEnglish

Summary

CAUTION

FCC Information

CANADA DOC Information

1.0 DESCRIPTION

Panel Features

Details supervisory, operational, programmable, and hardware features of the fire alarm control panel.

1.1 Components

Lists base panel capacities and various accessory/option modules for the 2400 series.

Module Descriptions

Details of specific modules like IDC, RCT, Dialer, ADM, ADS, RTU, and Remote Annunciators.

2.0 APPLICATION

Fire Alarm System Limitations

Discusses system purpose, component roles, and the need for preventive maintenance and testing.

3.0 THEORY OF OPERATION

Initiating Device Circuits (IDCs)

Explains IDC operation, zone types, and operating states for initiating devices.

Indicating Appliance Circuits (IACs)

Describes IAC operation, signaling appliance activation, and Class A wiring.

4.0 INSTALLATION

Installation Guidelines

Covers codes, standards, site storage, drawing references, mounting, power, and initial wiring instructions.

Panel Assembly and Module Installation

Procedures for assembling the base panel and installing option modules like IDC, ADM, RCT, and Dialer.

System Setup and Configuration

Steps for system power up, programming, field wiring, and panel function testing.

5.0 PROGRAMMING

Panel Programming

Guide to programming IDCs, IACs, system timers, and auxiliary power settings using panel switches.

Dialer Module Programming

Comprehensive guide for programming the DL1 Dialer Module, including CMS numbers, IDs, and retry settings.

Default Settings and Exiting

Procedures for returning to panel defaults and exiting the programming mode.

6.0 OPERATION

Panel Modes and Functions

Explains Normal, Alarm, Reset, Trouble, Supervisory, Drill, Disable, and Test modes, including LED indications.

7.0 TROUBLESHOOTING

Troubleshooting Guides

Tables correlating trouble LEDs, panel conditions, and dialer codes with their possible causes.

8.0 PREVENTIVE MAINTENANCE

Maintenance Schedule and Procedures

Schedule and procedures for routine maintenance, testing, and cleaning of system components.

Replacement Parts

List of related and spare parts available for the EDWARDS 2400 series panels and accessories.

9.0 SPECIFICATIONS

Base Panel and Module Specifications

Technical specifications for base panels, various modules (converters, IDC, RCT, ADM/ADS, Dialer), and battery cabinet.

Dialer Module Specifications

Detailed specifications for the DL1 Dialer Module, including communication protocols and dialer codes.

10.0 APPENDICES

Battery Calculations

Tables and worksheets to calculate required battery capacity based on panel configuration and operating modes.

Compatible Devices

Lists of ULI and ULC compatible initiating devices, signaling appliances, and accessories for use with the system.

Glossary and Standards

Definitions of technical terms and a list of relevant installation and operation standards from NFPA, UL, and ULC.

Configuration Worksheet

Worksheets for recording panel configuration, IDC programming, IAC programming, and option modules.